Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Application of single-antigen solid-phase immunoassay (SPI) in virtual crossmatch-based organ allocation has been hindered by continued debate over the biologic relevance of detected antibodies and the relationship between cutoff mean fluorescence intensity (MFI) values with crossmatch testing results. To define SPI parameters accurately predicting crossmatch testing, we analyzed a series of anti-HLA antibodies from highly-sensitized patients awaiting lung or heart transplantation. Serial dilution of serum for SPI and cytotoxic crossmatch (CXM) enabled comparison over a wide spectrum of antibody "strengths". Receiver operating characteristic (ROC) analysis identified predictive cutoff values for HLA Class I and DR-specific antibodies. However, antibodies to HLA-DQ antigens demonstrated a significantly different characteristic, highlighting difficulties in interpretation of clinical significance. We also quantitatively characterized two data handling methods, MFI ratio (MR) and relative ratio (RR), to examine their potential impact on identifying unacceptable antigens. In combination with user defined cutoff values, MFI, MR and RR lead to discordant identification of antibodies. Establishment of cutoff values for MR and RR that are comparable to MFI demonstrated increased consistency in antibody identification. This single laboratory experience is an example of establishing statistically robust cutoff values and validation across different data handling methods for use of SPI in virtual crossmatch.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.humimm.2012.04.016 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!