We report a temperature sensing system incorporated into an amperometric oxygen sensor. In the first part of this work, we introduce temperature sensing systems based upon voltammetric responses of both single molecule (1,2-diferrocenylethylene in 1-propyl-3-methylimidazolium bistrifluoromethylsulfonylimide) and two independent molecules (decamethylferrocene and N,N,N',N'-tetramethyl-p-phenylenediamine in 1-ethyl-3-methylimidazolium tetracyanoborate) respectively. In both systems, the difference in the formal potentials of two redox centres was measured as a function of temperature. The former was recorded as the peak difference in square wave voltammetry with the peak potential difference increases linearly with the increasing temperature. In order to show proof-of-concept in relation to a gas sensor, the latter system was investigated in the presence of oxygen, where the concentration and diffusion coefficient of oxygen varied with temperature, as well as the peak difference discussed previously, were studied in the presence of pure oxygen and dried air using chronoamperometry. A negligible variation of concentration of oxygen from both sources with temperature over the range 298 K to 318 K is demonstrated. These results obtained from pure oxygen and dried air were compared and a ca. 79% drop of cathodic signal from pure oxygen to dried air was found which is consistent with the percentage of oxygen in air. The diffusion coefficient of oxygen was related to temperature using an Arrhenius plot (natural log of diffusion coefficient as a function of reciprocal temperature), yielding a linear graph with high correlation. All experiments gave a high reproducibility.

Download full-text PDF

Source
http://dx.doi.org/10.1039/c2an35336aDOI Listing

Publication Analysis

Top Keywords

diffusion coefficient
12
pure oxygen
12
oxygen dried
12
dried air
12
temperature
9
oxygen
9
temperature sensing
8
peak difference
8
coefficient oxygen
8
electrochemical thermometer
4

Similar Publications

This contribution uses a rapid microwave-assisted hydrothermal synthesis method to produce a vanadium-based K1.92Mn0.54V2O5·H2O cathode material (quoted as KMnVOH).

View Article and Find Full Text PDF

Sub-micrometer LiPSCl regulated cathodic Li kinetics in sulfide based all-solid-state batteries.

Phys Chem Chem Phys

January 2025

School of Metallurgy and Environment, Central South University, Changsha, Hunan, 410083, P. R. China.

The practical applications of all-solid-state batteries (ASSBs) are hindered by poor Li kinetics in electrodes due to the inadequate contact between the cathode active materials (CAMs) and solid-state electrolytes (SSEs). Therefore, improving the contact interface between CAMs and SSEs is necessary to improve the cathodic Li kinetics by increasing the lithium-ion transport sites. To address this issue, sub-micrometer LiPSCl (SU-LPSC) particles of high specific areas were utilized to fabricate cathodes with high mass loading.

View Article and Find Full Text PDF

Innovation in the drying process during the roasting of cashew nut almonds has the potential to significantly improve product quality. This study aimed to investigate the drying kinetics of the almond, comparing the experimental data with the mathematical models of Fick, Page, Cavalcanti Mata, and Henderson and Pabis. The research was conducted at the Laboratory of Physical Measurements and Drying of the Academic Unit of Food Engineering at the Federal University of Campina Grande.

View Article and Find Full Text PDF

Background And Purpose: Diffusion tensor imaging (DTI) has been proposed to guide the anisotropic expansion from gross tumor volume to clinical target volume (CTV), aiming to integrate known tumor spread patterns into the CTV. This study investigate the potential of using a DTI atlas as an alternative to patient-specific DTI for generating anisotropic CTVs.

Materials And Methods: The dataset consisted of twenty-eight newly diagnosed glioblastoma patients from a Danish national DTI protocol with post-operative T1-contrast and DTI imaging.

View Article and Find Full Text PDF

Background: Computed tomography (CT) is the most common way to evaluate focal organizing pneumonia (FOP); however, sometimes it is difficult to differentiate FOP and peripheral lung carcinoma (PLC).

Purpose: To clarify the MRI manifestation of FOP and the value of MR in the differential diagnosis of FOP and PLC in comparison to CT.

Material And Methods: Chest MR (3D T1WI, T2WI TSE, DWI) and CT images of 72 patients (50 men: mean age=64.

View Article and Find Full Text PDF