A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Determination of (fluoro)quinolones in environmental water using online preconcentration with column switching linked to large sample volumes and fluorescence detection. | LitMetric

Determination of (fluoro)quinolones in environmental water using online preconcentration with column switching linked to large sample volumes and fluorescence detection.

J Sep Sci

Departamento de Hidrogeología y Química Analítica, Universidad de Almería, Campus de Excelencia Agroalimentario, La Cañada de San Urbano, Almería, Spain.

Published: April 2012

An analytical method based on online enrichment using coupled-column liquid chromatography with fluorescence detection has been developed to determine marbofloxacin, ciprofloxacin, danofloxacin, enrofloxacin, norfloxacin, lomefloxacin, oxolinic acid, and nalidixic acid at trace levels in surface water. The sample containing the pharmaceuticals was pumped through a short C18 column in such a way that the analytes were retained on the column, whereas polar interferences, eluting at the first of the chromatogram, were discarded to waste. Then, the analytes were transferred by the chromatographic mobile phase to a second C18 analytical column, where they were separated following a conventional chromatography. The optimized approach allowed to preconcentrate 15 mL of sample volume adjusted at acid pH with phosphoric acid and modified with 5% of methanol, at a flow rate of 1.5 mL/min in 10 min. R(2) values were between 0.994 and 0.998, detection and quantitation limits ranged between 0.001 and 0.080 and between 0.002 and 0.100 μg/L, respectively, and the interday precision was below 9.8%. Recoveries in three different surface water samples, spiked at concentration levels between 0.002 and 0.500 μg/L (n = 3 for each spiking level), ranged from 82.1 to 125.8% with the relative standard deviation lower than 12%.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jssc.201100911DOI Listing

Publication Analysis

Top Keywords

fluorescence detection
8
surface water
8
determination fluoroquinolones
4
fluoroquinolones environmental
4
environmental water
4
water online
4
online preconcentration
4
column
4
preconcentration column
4
column switching
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!