Exposure to specific airborne bacteria indoors is linked to infectious and noninfectious adverse health outcomes. However, the sources and origins of bacteria suspended in indoor air are not well understood. This study presents evidence for elevated concentrations of indoor airborne bacteria due to human occupancy, and investigates the sources of these bacteria. Samples were collected in a university classroom while occupied and when vacant. The total particle mass concentration, bacterial genome concentration, and bacterial phylogenetic populations were characterized in indoor, outdoor, and ventilation duct supply air, as well as in the dust of ventilation system filters and in floor dust. Occupancy increased the total aerosol mass and bacterial genome concentration in indoor air PM(10) and PM(2.5) size fractions, with an increase of nearly two orders of magnitude in airborne bacterial genome concentration in PM(10). On a per mass basis, floor dust was enriched in bacterial genomes compared to airborne particles. Quantitative comparisons between bacterial populations in indoor air and potential sources suggest that resuspended floor dust is an important contributor to bacterial aerosol populations during occupancy. Experiments that controlled for resuspension from the floor implies that direct human shedding may also significantly impact the concentration of indoor airborne particles. The high content of bacteria specific to the skin, nostrils, and hair of humans found in indoor air and in floor dust indicates that floors are an important reservoir of human-associated bacteria, and that the direct particle shedding of desquamated skin cells and their subsequent resuspension strongly influenced the airborne bacteria population structure in this human-occupied environment. Inhalation exposure to microbes shed by other current or previous human occupants may occur in communal indoor environments.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3329548 | PMC |
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0034867 | PLOS |
J Hazard Mater
January 2025
Monash Lung, Sleep, Allergy and Immunology, Monash Health, Melbourne, VIC, Australia; School of Clinical Sciences, Monash University, Melbourne, VIC, Australia; Monash Partners - Epworth, Melbourne, VIC, Australia.
Mitigation measures against infectious aerosols are desperately needed. We aimed to: 1) compare germicidal ultraviolet radiation (GUV) at 254 nm (254-GUV) and 222 nm (222-GUV) with portable high efficiency particulate air (HEPA) filters to inactivate/remove airborne bacteriophage ϕX174, 2) measure the effect of air mixing on the effectiveness of 254-GUV, and 3) determine the relative susceptibility of ϕX174, SARS-CoV-2, and Influenza A(H3N2) to GUV (254 nm, 222 nm). A nebulizer generated ϕX174 laden aerosols in an occupied clinical room (sealed-low flow).
View Article and Find Full Text PDFJ Hazard Mater
January 2025
The National Research Centre for the Working Environment, Lersø Parkallé 105, Copenhagen 2100, Denmark. Electronic address:
Wastewater treatment plant (WWTP) workers are exposed to bioaerosols containing bacteria, fungi, and endotoxin, potentially posing health risks to workers. This study quantified personal exposure levels to airborne bacteria and fungi, endotoxin, and dust among 44 workers during two seasons at four WWTPs. Associations between the exposure measurements and serum levels of biomarkers CRP, SAA, and CC16 were also assessed.
View Article and Find Full Text PDFSci Rep
January 2025
Aerosol Technology Laboratory, Biological and Agricultural Engineering Department, Texas A&M University, College Station, TX, 77843, USA.
Gram-negative bacteria pose an increased threat to public health because of their ability to evade the effects of many antimicrobials with growing antibiotic resistance globally. One key component of gram-negative bacteria resistance is the functionality and the cells' ability to repair the outer membrane (OM) which acts as a barrier for the cell to the external environment. The biosynthesis of lipids, particularly lipopolysaccharides, or lipooligosaccharides (LPS/LOS) is essential for OM repair.
View Article and Find Full Text PDFJ Toxicol Environ Health B Crit Rev
January 2025
Department of Biochemistry, Cancer Biology, Neuroscience & Toxicology, School of Medicine, Meharry Medical College, Nashville, TN, USA.
Particulate matter with an aerodynamic diameter of less than 2.5 µm (PM) is one of the criteria air pollutants that (1) serve as an essential carrier of airborne toxicants arising from combustion-related events including emissions from industries, automobiles, and wildfires and (2) play an important role in transient to long-lasting cognitive dysfunction as well as several other neurological disorders. A systematic review was conducted to address differences in study design and various biochemical and molecular markers employed to elucidate neurological disorders in PM -exposed humans and animal models.
View Article and Find Full Text PDFTuberculosis (Edinb)
January 2025
CSIR-Central Drug Research Institute, Lucknow, 226031, UP, India; Academy of Scientific and Innovative Research (AcSIR), Ghaziabad, 201002, UP, India. Electronic address:
The limitations of existing mouse models of lung infection with Mycobacteroides abscessus impede drug discovery and development. In contrast to current animal models that introduce NTM intravenously or by intranasal/intra-tracheal instillation or via bronchoscopy-guided insufflation, we developed a dry powder inhalation (DPI) of M. abscessus ATCC 19977 that generated paucibacillary lung infection and histopathology in immunocompetent mice.