Background: Many patient education materials (PEMs) available on the internet are written at high school or college reading levels, rendering them inaccessible to the average US resident, who reads at or below an 8(th) grade level. Currently, electronic health record (EHR) providers partner with companies that produce PEMs, allowing clinicians to access PEMs at the point of care.

Objective: To assess the readability of PEMs provided by a popular EHR vendor as well as the National Library of Medicine (NLM).

Design: We included PEMs from Micromedex, EBSCO, and MedlinePlus. Micromedex and EBSCO supply PEMs to Meditech, a popular EHR supplier in the US. MedlinePlus supplies the NLM. These PEM databases have high market penetration and accessibility.

Measurements: Grade reading level of the PEMs was calculated using three validated indices: Simple Measure of Gobbledygook (SMOG), Gunning Fog (GFI), and Flesch-Kincaid (FKI). The percentage of documents above target readability and average readability scores from each database were calculated.

Results: We randomly sampled 100 disease-matched PEMs from three databases (n = 300 PEMs). Depending on the readability index used, 30-100% of PEMs were written above the 8(th) grade level. The average reading level for MedlinePlus, EBSCO, and Micromedex PEMs was 10.2 (1.9), 9.7 (1.3), and 8.6 (0.9), respectively (p ≤ 0.000) as estimated by the GFI. Estimates of readability using SMOG and FKI were similar.

Conclusions: The majority of PEMS available through the NLM and a popular EHR were written at reading levels considerably higher than that of the average US adult.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3514986PMC
http://dx.doi.org/10.1007/s11606-012-2046-0DOI Listing

Publication Analysis

Top Keywords

pems
12
popular ehr
12
patient education
8
education materials
8
reading levels
8
8th grade
8
grade level
8
micromedex ebsco
8
reading level
8
readability
6

Similar Publications

Evaluating the feasibility of estimating particulate mass emissions of older-model diesel vehicle using smoke opacity measurements.

Sci Rep

December 2024

Clean Energy Technologies Research Institute (CETRI), Process Systems Engineering, Faculty of Engineering & Applied Science, University of Regina, 3737 Wascana Parkway, Regina, SK, S4S 0A2, Canada.

Real-world emissions of particulate matter (PM) and smoke opacity were studied for an older-model diesel pickup truck during four types of driving tests, namely fixed-point test, snap-acceleration test, road test, and hill road test (uphill/downhill). A portable emissions measurement system (PEMS) and an opacimeter were used to measure real-time concentrations of PM and smoke opacity, respectively, and simultaneously. Correlation analysis showed a significant positive association between PM and opacity, suggesting the feasibility of using an opacimeter to estimate PM mass emissions from diesel vehicles.

View Article and Find Full Text PDF

This study presents the preparation and electrochemical testing of sulfonated styrene-grafted poly(vinylidene fluoride) (pVDF) copolymers as proton exchange membranes (PEMs) for semi-organic redox flow batteries (RFBs) based on 9,10-anthraquinone-2,7-disulfonic acid (AQDS)/bromine. The copolymers are synthesized via a two-step procedure, involving i) atom transfer radical polymerization of styrene (Sty) for the grafting to the pVDF backbone and ii) the sulfonation of the polystyrene grafted side chains. Copolymers with different amounts of sulfonated styrene (SSty) in the side chains (i.

View Article and Find Full Text PDF

The impeding ban on per- and polyfluoroalkyl substances (PFAS) prompted researchers to focus on hydrocarbon-based materials as constituents of next-generation proton exchange membranes (PEMs) for polymer electrolyte fuel cells (PEFCs). Here, we report on the fuel cell performance and durability of fluorine-lean PEMs prepared by the post-sulfonation of co-grafted α-methylstyrene (AMS) and 2-methylene glutaronitrile (MGN) monomers into preirradiated 12 µm polyvinylidene fluoride (PVDF) base film. The membranes were subjected to two distinctly different accelerated stress test (AST) protocols performed at open-circuit voltage (OCV): the US Department of Energy-similar chemical AST (90 °C, 30% relative humidity (RH), H/air, 1 bar), developed originally for perfluoroalkylsulfonic acid (PFSA) membranes, and the high relative humidity AST (80 °C, 100% RH, H/O, 2.

View Article and Find Full Text PDF

Enhancing patient comprehension of their health is crucial in improving health outcomes. The integration of artificial intelligence (AI) in distilling medical information into a conversational, legible format can potentially enhance health literacy. This review aims to examine the accuracy, reliability, comprehensiveness and readability of medical patient education materials (PEMs) simplified by AI models.

View Article and Find Full Text PDF

Exposure of cell cultures at air-liquid interface (ALI), mimicking i.e. human lung surface, is believed to be one of the most realistic means to model toxicity of complex mixtures of pollutants on human health.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!