Purpose: To minimize the risk of chronic occupational exposure of antineoplastic drugs, cleaning procedures must be evaluated. This study was conducted to compare the detergent efficiency of cleaning solutions (two hydro-alcoholic solutions, three disinfectants and two detergents) used in different cleaning protocols.
Methods: The central surface of a stainless steel plate (30 × 50 cm) was exposed to a carboplatin solution equivalent to 105,100 ng of platinum. After cleaning according to a standardized protocol, residual platinum contaminations were assayed on 10 × 10 cm sections.
Results: After standardized cleaning, the residual quantity of platinum on the surface of the deposit accounted for between 1.0 and >15 % of the initial deposit. Spread of contamination on the plate depended on the cleaning movement and was between 2.1 and 53.9 % of the total quantity on the plate. The two detergents were more efficient (2,793-4,780 ng/plate) than hydro-alcoholic solutions (>20,000 ng/plate). The efficacy of the disinfectant was intermediate (5,891-6,122 ng/plate for solutions and 15,360 ng/plate for pre-soaked gauze). The cleaning protocol was also important with better efficiency of 8 mL of cleaning solution for 1,500 cm(2) (versus 4 mL), sprayed directly on the plate (versus wiping) with no contact time (versus 5 min).
Conclusion: The efficacy of chemical decontamination of cytotoxic work surfaces depends not only on the cleaning solution used, but also on the cleaning protocol. It is necessary to adapt the protocol to the surface to clean and it must be standardized and validated. This work is an example of an experimental procedure to evaluate the efficacy of cleaning solutions and protocols used at a workstation after exposure to antineoplastic drugs.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00420-012-0769-1 | DOI Listing |
BMC Oral Health
January 2025
Associate Professor of Operative Dentistry, Conservative Dentistry Department, Faculty of Oral and Dental Medicine Badr University in Cairo, Cairo, Egypt.
Background: Endodontic treatment aims in the preservation of extremely carious primary teeth. For root canal therapy to be successful, root canals must be properly prepared and effectively irrigated .Therefore, it is necessary to select the proper root canal disinfection method to preserve the primary tooth.
View Article and Find Full Text PDFSci Rep
January 2025
Department of Electronics and Communication Engineering, Panimalar Engineering College, Chennai, India.
The growing number of connected devices in smart home environments has amplified security risks, particularly from Man-in-the-Middle (MitM) attacks. These attacks allow cybercriminals to intercept and manipulate communication streams between devices, often remaining undetected. Traditional rule-based methods struggle to cope with the complexity of these attacks, creating a need for more advanced, adaptive intrusion detection systems.
View Article and Find Full Text PDFTalanta
January 2025
State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun, Jilin, 130022, China. Electronic address:
Flavonoid glycosides are formed by dehydration condensation of aglycones and sugar molecules. Therefore, discrimination of flavonoid glycosides from their corresponding aglycones is a challenging task because they contain the same aglycone part in their molecular structures. Herein, boric acid-functional Eu(III)-organic framework (BA-Eu-MOF) was applied to discriminate flavonoid glycosides including baicalin (Bai), wogonoside (Wog), rutin (Rut), puerarin (Pue), quercitrin (Que) and astragalin (Ast) from their corresponding aglycones for the first time.
View Article and Find Full Text PDFJ Hazard Mater
January 2025
Institute of Zhejiang University - Quzhou, No. 99 Zheda Road, Quzhou 324000, China; Key Laboratory of Biomass Chemical Engineering of Ministry of Education, College of Chemical and Biological Engineering, Zhejiang University, Hangzhou 310027, China. Electronic address:
The trichloroethylene production industry generates high-boiling-point solid residues during rectification, which contain high concentrations of chlorinated contaminants, particularly hexachlorobutadiene (HCBD). Traditionally, these distillation residues are managed through co-incineration or landfilling, leading to environmental and economic challenges. In this study, we present a rapid and environmentally friendly electrothermal approach for both detoxifying and upcycling distillation residue into graphene-based electromagnetic wave (EMW) absorbing materials.
View Article and Find Full Text PDFSci Total Environ
January 2025
Centre for Safety, Resilience and Protective Security, Fire Safety Engineering Group, School of Computing and Mathematical Sciences, Faculty of Engineering and Science, University of Greenwich, Greenwich SE10 9LS, United Kingdom.
Large passenger ships are characterised as enclosed and crowded indoor spaces with frequent interactions between travellers, providing conditions that facilitate disease transmission. This study aims to provide an indoor ship CO dataset for inferring thermal comfort, ventilation and infectious disease transmission risk evaluation. Indoor air quality (IAQ) monitoring was conducted in nine environments (three cabins, buffet, gym, bar, restaurant, pub and theatre), on board a cruise ship voyaging across the UK and EU, with the study conducted in the framework of the EU HEALTHY SAILING project.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!