Background: Experimental studies have shown that creating a window in the bony cover of the cochlea and vestibular parts of the inner ear, with preservation of membranous and middle-ear functions, induces an air-bone gap (ABG). This study sought to determine if a similar mechanism explains the ABG frequently observed in audiograms of cochlear implant candidates.

Method: The study group included 47 candidates for a cochlear implant (94 ears) attending a university-affiliated tertiary medical center who had an ABG component in the audiogram in the absence of external or middle-ear abnormalities. Air- and bone-conduction thresholds on pure-tone audiometry were analyzed for 250 to 8,000 Hz and 250 to 4,000 Hz, respectively. In the 25 patients operated on during the study period, differences in the ABG and in cerebrospinal fluid (CSF) leak were compared between those with and without anomalies on computed tomography.

Results: Imaging revealed an abnormal inner-ear structure in 46% of cases, mostly a large vestibular aqueduct, alone or combined with other cochlear or vestibular malformations. ABG was evident over high and low frequencies and was significantly larger at low frequencies and in ears with structural anomalies. A high rate of CSF leak was observed in patients with an ABG and structural anomalies imaging as well as in those with an ABG and normal imaging findings.

Conclusion: In cochlear implant candidates, the presence of a third window could cause an ABG because of stapes motion-induced shunting of acoustic energy outside the cochlear duct in response to air-conducted stimuli while bone conduction is preserved.

Download full-text PDF

Source
http://dx.doi.org/10.1097/MAO.0b013e3182544cbaDOI Listing

Publication Analysis

Top Keywords

cochlear implant
16
air-bone gap
8
audiograms cochlear
8
implant candidates
8
abg
8
csf leak
8
low frequencies
8
structural anomalies
8
cochlear
6
gap component
4

Similar Publications

This study (1) characterized the effects of channel interaction using spectral blurring, (2) evaluated an image-guided electrode selection (IGES) method aiming to reduce channel interaction, and (3) investigated the impact of electrode placement factors on the change in performance by condition. Twelve adult MED-EL (Innsbruck, Austria) cochlear implant recipients participated. Performance was compared across six conditions: baseline (no blurring), all blurred, apical blurred, middle blurred, basal blurred, and IGES.

View Article and Find Full Text PDF
Article Synopsis
  • Malawi started its cochlear implantation program in 2014, and the number of children using the implants has increased, allowing for a better assessment of hearing outcomes.
  • Nineteen children with severe-to-profound deafness were studied, showing significant improvements in hearing thresholds after receiving unilateral cochlear implants, indicated by a reduction in mean PTA thresholds from 110.8 dB to 37.8 dB.
  • The study concluded that Malawi's cochlear implantation program is effective in treating hearing loss in children, but challenges still exist for further program expansion.
View Article and Find Full Text PDF

Spontaneous Hearing Recovery Two Years Following Onset of Bilateral Sudden Sensorineural Hearing Loss: Miracle May Happen any Time.

Mymensingh Med J

January 2025

Dr Md Harun Ar Rashid Talukder, Associate Professor (Otology), Department of Otolaryngology-Head & Neck Surgery, BSMMU, Dhaka, Bangladesh, Dhaka, Bangladesh; E-mail:

Sudden sensorineural hearing loss is a medical emergency. Incidence is very low. Unilateral SSNHL is common and mostly idiopathic.

View Article and Find Full Text PDF

Post mortem cadaveric and imaging mapping analysis of the influence of cochlear implants on cMRI assessment regarding implant positioning and artifact formation.

Eur Arch Otorhinolaryngol

December 2024

Department of Otorhinolaryngology - Head and Neck Surgery, Medical Center, Faculty of Medicine, University of Freiburg, Killianstrasse 5, 79106, Freiburg, Germany.

Objectives: In times of an aging society and considering the escalating health economic costs, the indications for imaging, particularly magnetic resonance imaging (MRI), must be carefully considered and strictly adhered to. This cadaver study aims to examine the influence of cochlear implant (CI) on the assessment of intracranial structures, artifact formation, and size in cranial MRI (cMRI). Furthermore, it seeks to evaluate the potential limitations in the interpretability and diagnostic value of cMRI in CI patients.

View Article and Find Full Text PDF

Thermally Drawn Shape and Stiffness Programmable Fibers for Medical Devices.

Adv Healthc Mater

December 2024

Department of Metabolism, Digestion, and Reproduction, Faculty of Medicine, Imperial College London, London, SW7 2AZ, UK.

Despite the significant advantages of Shape Memory Polymers (SMPs), material processing and production challenges have limited their applications. Recent advances in fiber manufacturing offer a novel approach to processing polymers, broadening the functions of fibers beyond optical applications. In this study, a thermal drawing technique for SMPs to fabricate Shape Memory Polymer Fibers (SMPFs) tailored for medical applications, featuring programmable stiffness and shape control is developed.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!