AI Article Synopsis

  • The study aimed to assess the effectiveness of fetal echocardiography alongside other screening methods in detecting Down’s syndrome (DS) and chromosomal disorders in pregnant women.
  • During a 5-year period, 17,911 participants underwent combined testing (CT) and modified genetic sonography (MGS), revealing a significant sensitivity increase when adding fetal echocardiography to the screening process.
  • The findings concluded that fetal echocardiography greatly enhances the detection rates of DS and chromosomal disorders, demonstrating its value in comprehensive prenatal screening strategies.

Article Abstract

Objectives: To evaluate the contribution made by fetal echocardiography in identifying Down's syndrome (DS) and other chromosomal disorders in a stepwise sequential screening method (first step: combined test (CT), second step: modified genetic sonography (MGS) (major malformation and nuchal fold)), for DS in the general population of pregnant women.

Methods: Prospective study. During a 5-year study period (July 2005-June 2010) 17,911 pregnant women underwent CTs with MGS (with fetal cardiac morphological evaluation performed by obstetricians in a tertiary hospital) as a screening method for DS. We evaluated the sensitivity and false positive rate (FPR) (95% confidence interval (CI)) of three screening methods for DS and all chromosomal disorders: CT, CT + MGS, and CT + fetal echocardiography.

Results: A total of 17,911 cases were analyzed with 67 chromosome disorders and 45 DS cases being found. For DS, the CT sensitivity was 80% (95% CI; 68.3-91.7) (36/45) and 79.1% (95% CI; 69.4-88.8) (53/67) for all chromosome disorders, with a FPR of 4.2% (95% CI; 3.9-4.5) (752/17,866) and 4.1% (95% CI; 3.8-4.4) (735/17,844), respectively. For CT + MSG and CT + fetal echocardiography, the sensitivity for DS was 93.3% (95% CI; 85.9-0.99) (42/45) and 95.5% (95% CI; 90.5-0.99) (64/67) for all chromosome disorders. The FPR for CT + MSG was 4.8% (95% CI; 4.5-5.1) (860/17,866) and 4.6% (95% CI; 4.3-4.9) (836/17,844), respectively. The FPR of CT + fetal echocardiography was 4.4% (95% CI; 4.1-4.7) (792/17,866) for DS screening and 4.3% (95% CI; 4-4.6) (770/17,844) for chromosome abnormality screening.

Conclusions: Fetal echocardiography is highly capable of identifying DS and other chromosomal disorders as a part of genetic sonography in stepwise sequential screening.

Download full-text PDF

Source
http://dx.doi.org/10.3109/14767058.2012.684167DOI Listing

Publication Analysis

Top Keywords

fetal echocardiography
20
chromosomal disorders
16
stepwise sequential
12
sequential screening
12
genetic sonography
12
chromosome disorders
12
95%
11
combined test
8
modified genetic
8
screening method
8

Similar Publications

Pulmonary atresia with ventricular septal defect (PA-VSD) is usually diagnosed by transthoracic or fetal echocardiography, with the prenatal diagnosis being feasible and accurate if fetal cardiology services are available. The limitations of transthoracic echocardiography (TTE) in the evaluation of PA-VSD include the complete evaluation of the pulmonary arteries and patent ductus arteriosus, quantitative evaluation of the right ventricle size and function, and delineation of associated cardiac anomalies such as coronary artery anomalies, anomalies of systemic or pulmonary venous return, and complex arch anomalies. Echocardiography also has limitations in evaluating hemodynamics such as flow volumes, shunts, and regurgitant fraction.

View Article and Find Full Text PDF

Background: Cardiovascular disease (CVD) remains the leading cause of death in pregnant and peripartal women in western countries. Physiological changes during pregnancy can lead to cardiovascular complications in the mother; women with pre-existing heart disease may not tolerate these changes well, increasing their susceptibility to adverse cardiovascular outcomes during pregnancy. The aim of this study is to characterize pregnancy-induced changes in cardiac function, biomarker concentrations and cardiovascular outcomes in women with CVD during pregnancy at a tertiary care hospital in Germany.

View Article and Find Full Text PDF

Congenital heart defects (CHDs) are the most common congenital defect, occurring in approximately 1 in 100 live births and being a leading cause of perinatal morbidity and mortality. Of note, approximately 25% of these defects are classified as critical, requiring immediate postnatal care by pediatric cardiology and neonatal cardiac surgery teams. Consequently, early and accurate diagnosis of CHD is key to proper prenatal and postnatal monitoring in a tertiary care setting.

View Article and Find Full Text PDF

Our primary objective was to assess the effectiveness of detailed cardiovascular ultrasound screening during the first trimester, which was performed by obstetricians with intermediate experience. We collected first-trimester fetal cardiac screening data from an unselected pregnant population at RMC-Fetal Medicine Center during a study period spanning from 1 January 2010, to 31 January 2015, in order to analyze our learning curve. A pediatric cardiologist performed a follow-up assessment in cases where the examining obstetrician determined that the fetal cardiac screening results were abnormal or high-risk.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!