A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

The mode of death in implantable cardioverter-defibrillator and cardiac resynchronization therapy with defibrillator patients: results from routine clinical practice. | LitMetric

Background: Although data on the mode of death of implantable cardioverter-defibrillator (ICD) and cardiac resynchronization therapy with defibrillator (CRT-D) patients have been examined in randomized clinical trials, in routine clinical practice data are scarce. To provide reasonable expectations and prognosis for patients and physicians, this study assessed the mode of death in routine clinical practice.

Objective: To assess the mode of death in ICD/CRT-D recipients in routine clinical practice.

Methods: All patients who underwent an ICD or CRT-D implantation at the Leiden University Medical Center, the Netherlands, between 1996 and 2010 were included. Patients were divided into primary prevention ICD, secondary prevention ICD, and CRT-D patients. For patients who died during follow-up, the mode of death was retrieved from hospital and general practitioner records and categorized according to a predetermined classification: heart failure death, other cardiac death, sudden death, noncardiac death, and unknown death.

Results: A total of 2859 patients were included in the analysis. During a median follow-up of 3.4 years (interquartile range 1.7-5.7 years), 107 (14%) primary prevention ICD, 253 (28%) secondary prevention ICD, and 302 (25%) CRT-D recipients died. The 8-year cumulative incidence of all-cause mortality was 39.9% (95% confidence interval 37.0%-42.9%). Heart failure death and noncardiac death were the most common modes of death for all groups. Sudden death accounted for approximately 7%-8% of all deaths.

Conclusion: For all patients, heart failure and noncardiac death are the most common modes of death. The proportion of patients who died suddenly was low and comparable for primary and secondary ICD and CRT-D patients.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.hrthm.2012.04.021DOI Listing

Publication Analysis

Top Keywords

mode death
20
routine clinical
16
prevention icd
16
death
14
crt-d patients
12
icd crt-d
12
heart failure
12
noncardiac death
12
patients
11
death implantable
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!