Background: Left ventriculography provided the first imaging of left ventricular function and was historically performed as part of coronary angiography despite a small but significant risk of complications. Because modern noninvasive imaging techniques are more accurate and carry smaller risks, the routine use of left ventriculography is of questionable utility. We sought to analyze the frequency that left ventriculography was performed during coronary angiography in patients with and without a recent alternative assessment of left ventricular function.
Methods: We performed a retrospective analysis of insurance claims data from the Aetna health care benefits database including all adults who underwent coronary angiography in 2007. The primary outcome was the concomitant use of left ventriculography during coronary angiography.
Results: Of 96,235 patients who underwent coronary angiography, left ventriculography was performed in 78,705 (81.8%). Use of left ventriculography was high in all subgroups, with greatest use in younger patients, those with a diagnosis of coronary disease, and those in the Southern United States. In the population who had undergone a very recent ejection fraction assessment by another modality (within 30 days) and who had had no intervening diagnosis of new heart failure, myocardial infarction, hypotension, or shock (37,149 patients), left ventriculography was performed in 32,798 patients (88%)-a rate higher than in the overall cohort.
Conclusions: Left ventriculography was performed in most coronary angiography cases and often when an alternative imaging modality had been recently completed. New clinical practice guidelines should be considered to decrease the overuse of this invasive test.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.ahj.2011.12.018 | DOI Listing |
Turk Kardiyol Dern Ars
January 2025
Department of Cardiology, Gülhane Faculty of Medicine, University of Health Sciences, Ankara, Türkiye.
Severe mitral regurgitation (MR) following surgical repair of the mitral valve poses a significant clinical challenge. Patients who have undergone surgery are typically at high risk for a second operation. This report details the case of a 54-year-old male who underwent aortic valve replacement and mitral valve repair using a 34-ring, 14 years prior.
View Article and Find Full Text PDFEur Heart J Case Rep
November 2024
Department of Cardiology, Glenfield Hospital, University Hospitals of Leicester, Leicester LE3 9QP, UK.
Eur Heart J Case Rep
November 2024
Department of Cardiology, Aso Iizuka Hospital, 3-83 Yoshio-machi, Iizuka, Fukuoka 820-8505, Japan.
Background: It is reasonable to introduce a microaxial flow pump (Impella) before coronary angiography and left ventriculography (LVG) to prioritize treating tissue hypoperfusion in patients with takotsubo syndrome (TTS) and refractory cardiogenic shock. However, left ventricular (LV) unloading by an Impella device might prevent contrast media from filling the left ventricle, making it difficult to evaluate LV wall motion abnormalities during LVG.
Case Summary: A 76-year-old female with ST elevations in I, II, aVL, and V1-6 on electrocardiography and severe LV dysfunction on echocardiography immediately received circulatory support with Impella CP to treat refractory cardiogenic shock.
Heliyon
October 2024
Division of Radiology, Asahi General Hospital, Asahi, Japan.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!