The dose for image-based motion monitoring of prostate tumours during radiotherapy delivery has not been established. This study aimed to provide quantitative analysis and optimization of the fluoroscopic patient imaging dose during radiotherapy for IMRT and VMAT treatments using standard and hypofractionated treatment schedules. Twenty-two patients with type T1c N0/M0 prostate cancer and three implanted fiducial markers were considered. Minimum field sizes encompassing all fiducial markers plus a 7.5 mm motion margin were determined for each treatment beam, each patient and the complete cohort. Imaging doses were measured for different field sizes and depths in a phantom at 75 and 120 kV. Based on these measurements, the patient imaging doses were then estimated according to beam-on time for clinical settings. The population minimum field size was 5.3 × 6.1 cm², yielding doses of 406 and 185 mGy over the course of an IMRT treatment for 75 kV (10 mAs) and 120 kV (1.04 mAs) imaging respectively, at 1 Hz. The imaging dose was reduced by an average of 28% and 32% by adopting patient-specific and treatment-beam-specific field sizes respectively. Standard fractionation VMAT imaging doses were 37% lower than IMRT doses over a complete treatment. Hypofractionated IMRT stereotactic body radiotherapy (SBRT) and VMAT SBRT imaging doses were 58% and 76% lower than IMRT doses respectively. The patient dose for kilovoltage intrafraction monitoring of the prostate was quantified. Tailoring imaging field sizes to specific patients yielded a significant reduction in the imaging dose, as did adoption of faster treatment modalities such as VMAT.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3369877PMC
http://dx.doi.org/10.1088/0031-9155/57/10/2969DOI Listing

Publication Analysis

Top Keywords

imaging dose
16
field sizes
16
imaging doses
16
patient imaging
12
monitoring prostate
12
imaging
10
fiducial markers
8
minimum field
8
lower imrt
8
imrt doses
8

Similar Publications

Intracardiac echocardiography (ICE) has been used to guide radio-frequency catheter ablation (RFCA) for better catheter navigation and less radiation exposure in treating atrial fibrillation (AF). This retrospective cohort study enrolled 227 AF patients undergoing ICE- or traditional fluoroscopy (TF)-guided RFCA for AF in a tertiary hospital. ICE was used more often in patients with atrial tachycardia [odds ratio (OR) 3.

View Article and Find Full Text PDF

Despite numerous studies investigating the correlation between the serum uric acid and high-density lipoprotein cholesterol ratio (UHR) and fatty liver disease, the evidence for the dose-response relationship between UHR and liver fat content (LFC) remains uncertain. This study employs quantitative computed tomography (CT) to quantify LFC and aims to investigate the correlation and dose-response relationship between UHR levels and LFC in Chinese adults. Based on the health check-up data from 2021 at Henan Provincial People's Hospital, China, the objective of this cross-sectional study was to investigate the association between UHR levels and LFC among individuals of different genders.

View Article and Find Full Text PDF

Despite decades of improvements in cytotoxic therapy, the current standard of care for locally advanced pancreatic cancer (LAPC) provides, on average, only a few months of survival benefit. Stereotactic Body Radiation Therapy (SBRT), a technique that accurately delivers high doses of radiation to tumors in fewer fractions, has emerged as a promising therapy to improve local control of LAPC; however, its effects on the tumor microenvironment and hypoxia remain poorly understood. To explore how SBRT affects pancreatic tumors, we combined an orthotopic mouse model of pancreatic cancer with an intravital microscopy platform to visualize changes to the in vivo tumor microenvironment in real-time.

View Article and Find Full Text PDF

Radiomics models based on thoracic and upper lumbar spine in chest LDCT to predict low bone mineral density.

Sci Rep

December 2024

Center for Rehabilitation Medicine, Department of Radiology, Zhejiang Provincial People's Hospital (Affiliated People's Hospital), Hangzhou Medical College, Hangzhou, 310014, Zhejiang, China.

This study aims to develop and validate different radiomics models based on thoracic and upper lumbar spine in chest low-dose computed tomography (LDCT) to predict low bone mineral density (BMD) using quantitative computed tomography (QCT) as standard of reference. A total of 905 participants underwent chest LDCT and paired QCT BMD examination were retrospectively included from August 2018 and June 2019. The patients with low BMD (n = 388) and the normal (n = 517) were randomly divided into a training set (n = 622) and a validation set (n = 283).

View Article and Find Full Text PDF

Background: Intermediate-high risk pulmonary embolism (PE) carries a significant risk of hemodynamic deterioration or death. Treatment should balance efficacy in reducing clot burden with the risk of complications, particularly bleeding. Previous studies on high-dose, short-term thrombolysis with alteplase (rtPA) showed a reduced risk of hemodynamic deterioration but no change in mortality and increased bleeding complications.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!