The present study is focused on the implementation of a novel, low cost, urban grid of nanostructured chemresistor gas sensors for ammonia concentration ([NH(3)]) monitoring, with NH(3) being one of the main precursors of secondary fine particulate. Low-cost chemresistor gas sensors based on carbon nanotubes have been developed, their response to [NH(3)] in the 0.17-5.0 ppm range has been tested, and the devices have been properly calibrated under different relative humidity conditions in the 33-63% range. In order to improve the chemresistor selectivity towards [NH(3)], an Expert System, based on fuzzy logic and genetic algorithms, has been developed to extract the atmospheric [NH(3)] (with a sensitivity of a few ppb) from the output signal of a model chemresistor gas sensor exposed to an NO(2), NO(X) and O(3) gas mixture. The concentration of these pollutants that are known to be the most significant interfering compounds during ammonia detection with carbon nanotube gas sensors has been tracked by the ARPA monitoring network in the city of Milan and the historical dataset collected over one year has been used to train the Expert System.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1039/c2em30102d | DOI Listing |
Bioelectrochemistry
January 2025
Department of Mechanical Engineering, Ajou University, South Korea. Electronic address:
Bloodstream bacterial infections, a major health concern due to rising sepsis rates, require prompt, cost-effective diagnostics. Conventional methods, like CO-based transduction, face challenges such as volatile metabolites, delayed gas-phase signaling, and the need for additional instruments, whereas electrochemical sensors provide rapid, sensitive, and efficient real-time detection. In this study, we developed a bioreceptor-free Prussian blue (PB) sensor platform for real-time bacterial growth monitoring in blood culture.
View Article and Find Full Text PDFLuminescence
January 2025
Faculty of Materials Science and Chemistry, China University of Geosciences, Wuhan, China.
Currently, the development of red Mn-activated fluoride luminescent materials attracts a lot of attention in optical thermometry sensors, solid lighting, display, and plant growth areas. Nevertheless, the thermal stability of Mn-activated fluoride luminescent materials is still a crucial issue. Herein, a new red RbNaVF:Mn luminescent material with outstanding thermal stability was successfully synthesized through the facial coprecipitation method.
View Article and Find Full Text PDFSensors (Basel)
January 2025
Phillip M. Drayer Electrical Engineering Department, Lamar University, Beaumont, TX 77705, USA.
Automated ultrasonic testing (AUT) is a critical tool for infrastructure evaluation in industries such as oil and gas, and, while skilled operators manually analyze complex AUT data, artificial intelligence (AI)-based methods show promise for automating interpretation. However, improving the reliability and effectiveness of these methods remains a significant challenge. This study employs the Segment Anything Model (SAM), a vision foundation model, to design an AI-assisted tool for weld defect detection in real-world ultrasonic B-scan images.
View Article and Find Full Text PDFSensors (Basel)
January 2025
Department of Electrical Engineering, Technical University Eindhoven, 5612 AZ Eindhoven, The Netherlands.
The effects of mechanical vibrations on control system stability could be significant in control systems designed on the assumption of rigid-body dynamics, such as launch vehicles. Vibrational loads can also cause damage to launch vehicles due to fatigue or excitation of structural resonances. This paper investigates a method to control structural vibrations in real time using a finite number of strain measurements from a fiber Bragg grating (FBG) sensor array.
View Article and Find Full Text PDFSensors (Basel)
January 2025
State Key Laboratory of Petroleum Resources and Prospecting, China University of Petroleum, Beijing 102249, China.
Transducers used in acoustic logging while drilling (ALWD) must be mounted on a drill collar, and their radiation performance is dependent on the employed mounting method. Herein, the complex transmitting voltage response of a while-drilling (WD) monopole acoustic source was calculated through finite-element harmonic-response analysis. Subsequently, the acoustic pressure waveform radiated by the source driven by a half-sine excitation voltage signal was calculated using the complex transmitting voltage response.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!