A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Rapid determination of vitamin B12 concentration with a chemiluminescence lab on a chip. | LitMetric

This paper reports a novel method for the rapid determination of vitamin B(12) concentration in a continuous-flow lab-on-a-chip system. This new method is based on luminol-peroxide chemiluminescence (CL) assays for the detection of cobalt(II) ions in vitamin B(12) molecules. The lab-on-a-chip device consisted of two passive micromixers acting as microreactors and a double spiral microchannel network serving as an optical detection region. This system could operate in two modes. In the first mode, samples are acidified and evaluated directly in the microchip. In the second mode, samples are treated externally by acidification prior to detection in the microchip. In the first mode, the linear range obtained was between 1.00 ng ml(-1) to 10 μg ml(-1), R(2) = 0.996, with a relative standard deviation (RSD) of 1.23 to 2.31% (n = 5) and a limit of detection (lod) of 0.368 pg ml(-1). The minimum sample volume required and the analytical time were 30 μl and 3.6 s, respectively. In the second mode, the linear range obtained was between 0.10 ng ml(-1) to 10 μg ml(-1), R(2) = 0.994, with the RSD of 0.90 to 2.32% (n = 6) and a lod of 0.576 pg ml(-1). The minimum sample and the analytical time required were 50 μl and 6 s, respectively. The lab on a chip working in mode II was successfully used for the determination of vitamin B(12) concentrations in nutritional supplemental tablets and hen egg yolks.

Download full-text PDF

Source
http://dx.doi.org/10.1039/c2lc00037gDOI Listing

Publication Analysis

Top Keywords

vitamin b12
16
determination vitamin
12
rapid determination
8
b12 concentration
8
lab chip
8
mode samples
8
second mode
8
mode linear
8
linear range
8
ml-1 μg
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!