A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Biomechanical rationale for six splinted implants in bilateral canine, premolar, and molar regions in an edentulous maxilla. | LitMetric

Purpose: To determine the influence of number and location of implants loaded on the stress to the bone in an edentulous maxilla using a three-dimensional finite element model (3D FEM).

Material And Methods: Computed tomographic data with the bone density of a dry skull were used to construct a 3D FEM. Titanium implants were simulated in the configuration as 14 unsplinted implants (US14), 14 splinted implants (S14), 6 splinted implants (canine, premolar, and molar regions, S6), 4 splinted implants (S4), and 6 anterior implants (incisors and canines, A6). Distributed loads of 200 N were applied on the occlusal table of the superstructures.

Results: The S6 model was subjected to a similar amount of stress and deformation to the US14 and the S14. The S4 and A6 models were subjected to approximately three times of stress under the vertical load, and approximately five times of stress under the inclined load, respectively, compared with the S6 model.

Conclusions: The 3D FEM analyses suggest that the six splinted implants configuration has a similar stress and deformation pattern as compared with naturally positioned splinted 14 implants in the edentulous maxilla.

Download full-text PDF

Source
http://dx.doi.org/10.1097/ID.0b013e31825023f5DOI Listing

Publication Analysis

Top Keywords

splinted implants
24
edentulous maxilla
12
implants
10
canine premolar
8
premolar molar
8
molar regions
8
stress deformation
8
times stress
8
splinted
6
stress
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!