Flow-diverting devices offer an exciting alternative for the management of large and giant intracranial aneurysms. However, the risk and mechanism of delayed aneurysmal rupture and hemorrhage following placement of these devices are not clearly understood. Two patients with similar symptomatic giant paraclinoid internal carotid artery aneurysms are described. Both patients were treated with SILK flow-diverting devices. In both patients the SILK device was placed without technical complication. The first patient continued to do well 1 year postoperatively with complete aneurysm occlusion. The second patient had a delayed subarachnoid hemorrhage despite markedly decreased filling of the aneurysm immediately following the procedure. Flow-diverting devices are an exciting technology which provide an alternative treatment modality in the management of giant intracranial aneurysms. However, caution must be exercised as the risks of delayed complications have yet to be fully elucidated. Similar aneurysms may have drastically different outcomes due to the unpredictability of this technology.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1136/neurintsurg-2012-010316 | DOI Listing |
Clin Neuroradiol
January 2025
Department of Neuroradiology, The Walton Centre for Neurology and Neurosurgery, Liverpool, UK.
Purpose: The aim of our study was to assess the mid-term efficacy and safety of the FRED X flow diverting stent (FDS) in the treatment of intracranial aneurysms. The FRED X FDS is relatively new with limited data on its longer-term effectiveness and safety profile.
Methods: Patients with intracranial aneurysms treated with the FRED X FDS at two UK centres, between March 2021 and July 2022 with at least 18 months follow-up, were retrospectively reviewed.
Int J Numer Method Biomed Eng
January 2025
Department of Radiology, Mayo Clinic, Rochester, Minnesota, USA.
As the number of cerebral aneurysms treated with flow diverters continues to increase, it is important to understand what factors influence not only thrombus formation within the aneurysm cavity but also fibrin accumulation across the device and its associated disruption and blockage of the inflow stream. Both processes contribute to the eventual occlusion of the aneurysm or its continued patency and incomplete occlusion which may require future re-treatment. To investigate fibrin accumulation on flow diverters placed across the neck of cerebral aneurysms, a previously developed computational model that couples flow and fibrin dynamics is used in combination with experimental in vitro models of cerebral aneurysms treated with flow diverters.
View Article and Find Full Text PDFJ Neurol Sci
January 2025
Department of Neurological Surgery, Thomas Jefferson University Hospital, Philadelphia, PA, USA. Electronic address:
Introduction: The FRED-X is a newer generation flow diverting stent (FDS) with surface modification that has demonstrated favorable efficacy in treating intracranial aneurysms. Our study provides an analysis of patients treated using FRED-X compared to FRED, PED Shield and PED.
Materials And Methods: This was a retrospective single center study and a systematic review with network meta analysis of patients who underwent flow diversion using FRED-X, FRED, PED Shield or PED.
J Neurointerv Surg
January 2025
UOSA Neuroradiologia Interventistica, Fondazione Policlinico Universitario Agostino Gemelli IRCCS Roma, Roma, Italy
Background: Data about the safety and the efficacy of flow diversion for distal anterior cerebral artery (DACA) aneurysms are limited. We present the largest multicenter analysis evaluating the outcomes of flow diversion in unruptured DACA aneurysm treatment.
Methods: Databases from 39 centers were retrospectively reviewed for unruptured DACA aneurysms treated with flow-diverting stents.
BMJ Case Rep
December 2024
Pontificia Universidad Catolica del Ecuador, Quito, Pichincha, Ecuador.
Carotid-cavernous aneurysms (CCAs) have the potential for growth, and their risk of rupture can lead to severe complications. Treatment is typically recommended to prevent these complications, with endovascular therapy being the preferred approach due to the challenging surgical access. This case presents a rare instance of rupture of a CCA that had been previously treated with a flow-diverting stent, which resulted in the development of a carotid-cavernous fistula, requiring venous access endovascular treatment.