Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Aims: To analyse the vasoreactivity of a coronary segment, previously scaffolded by the ABSORB bioresorbable vascular scaffold (BVS) device, in relationship to its intravascular ultrasound-virtual histology (IVUS-VH) composition and reduction in greyscale echogenicity of the struts. Coronary segments, transiently scaffolded by a polymeric device, may in the long-term recover a normal vasomotor tone. Recovery of a normal endothelial-dependent vasomotion may be enabled by scaffold bioresorption, composition of the underlying tissue, or a combination of both mechanisms.
Methods And Results: All patients from the ABSORB Cohort A and B trials, who underwent a vasomotion test and IVUS-VH investigation at 12 and 24 months, were included. Acetylcholine (Ach) and nitroglycerin were used to test either the endothelial-dependent or -independent vasomotion of the treated segment. Changes in polymeric strut echogenicity-a surrogate for bioresorption-IVUS-VH composition of the tissue underneath the scaffold and their relationship with the pharmacologically induced vasomotion were all evaluated. Overall, 26 patients underwent the vasomotion test (18 at 12 and 8 at 24 months). Vasodilatory response to Ach was quantitatively associated with larger reductions over time in polymeric strut echogenicity (y= -0.159x- 6.85; r= -0.781, P< 0.001). Scaffolded segments with vasoconstriction to Ach had larger vessel areas (14.37 ± 2.50 vs. 11.85 ± 2.54 mm(2), P= 0.030), larger plaque burden (57.31 ± 5.96 vs. 49.09 ± 9.10%, P= 0.018), and larger necrotic core (NC) areas [1.39 (+1.14, +1.74) vs. 0.78 mm(2) (+0.20, +0.98), P= 0.006] compared with those with vasodilation.
Conclusion: Vasodilatory response to Ach, in coronary segments scaffolded by the ABSORB BVS device, is associated with a reduction in echogenicity of the scaffold over time, and a low amount of NC. In particular, the latter finding resembles the behaviour of a native coronary artery not caged by an intracoronary device.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1093/eurheartj/ehr466 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!