Occlusion on implants - is there a problem?

J Oral Rehabil

Westmead Centre for Oral Health, Faculty of Dentistry, The University of Sydney, Westmead, NSW, Australia.

Published: July 2012

Oral rehabilitation restores form and function and impacts on general health. Teeth provide a discriminating sense of touch and directional specificity for occlusal perception, management of food with mastication and swallowing, and awareness of its texture and hardness. Peripheral feedback for control of jaw muscles includes the enamel-dentine-pulp complex and mechanoreceptors in the periodontal tissues. The implications of feedback from periodontal and other intra-oral mechanoreceptors as well as changes in central representation are significant for function and adaptation to oral rehabilitation. With implants, in the absence of the periodontium and periodontal mechanoreceptor feedback, fine motor control of mastication is reduced, but patients are still able to function adequately. Further, there is no significant difference in function with full-arch fixed prostheses on teeth in comparison with implants. Predictable implant outcomes depend on bone support. Optimum restoration design appears to be significant for bone remodelling and bone strains around implants with occlusal loading. Finite element analysis data confirmed load concentrations at the coronal bone around the upper section of the implant where bone loss is commonly observed clinically. Load concentration increased with steeper cusp inclination and broader occlusal table and decreased with central fossa loading and narrower occlusal table size. It is recommended that occlusal design should follow a narrow occlusal table, with central fossa loading in intercuspal contact and low cusp inclination to minimise lateral loading in function and parafunction. Acknowledging these features should address potential problems associated with the occlusion in implant therapy.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1365-2842.2012.02305.xDOI Listing

Publication Analysis

Top Keywords

occlusal table
12
oral rehabilitation
8
cusp inclination
8
central fossa
8
fossa loading
8
occlusal
6
function
5
bone
5
occlusion implants
4
implants problem?
4

Similar Publications

Conservative versus Invasive Approaches in Temporomandibular Disc Displacement: A Systematic Review of Randomized Controlled Clinical Trials.

Dent J (Basel)

July 2024

Experimental Biology Unit, Department of Biomedicine, Faculty of Medicine of Porto, University of Porto, 4200-319 Porto, Portugal.

Background: Temporomandibular disorders (TMDs) frequently cause orofacial pain and dysfunction, with treatment options spanning from conservative therapies to invasive surgical procedures. The aim of this systematic review was to analyze and compare the efficacy and safety profiles of conservative, minimally invasive interventions and surgical procedures in patients diagnosed with TMDs and disc displacement.

Methods: Following PRISMA recommendations, PubMed, Scopus, and Web of Science databases were searched for randomized clinical trials (RCT).

View Article and Find Full Text PDF

Changes in 3-Dimensional Measurements of Masseter Muscle After Orthognathic Surgery in Patients with Facial Asymmetry.

Aesthetic Plast Surg

October 2024

Department of Oral and Maxillofacial Surgery, Guangzhou Key Laboratory of Basic and Applied Research of Oral Regenerative Medicine, Affiliated Stomatology Hospital of Guangzhou Medical University, Guangzhou, 510150, China.

Article Synopsis
  • The study aimed to evaluate changes in the masseter muscle in patients with facial asymmetry using 3D analysis, focusing on factors influencing these changes before and after orthognathic surgery.
  • A cohort of 22 patients showed significant reductions in masseter muscle volume and cross-sectional area on the non-deviated side post-surgery, while the deviated side experienced an increase in length.
  • Results indicated that masseter muscle asymmetry could be improved through maxilla-mandible correction, with greater muscle atrophy linked to a larger inclined occlusal plane angle after surgery.
View Article and Find Full Text PDF

Purpose: To compare and analyze the orthodontic effects of micro-implant screw support and flat guide plate on excessive deep overbite of lower anterior teeth.

Methods: Eighty-two patients with excessive deep overbite of the lower anterior teeth who were treated from January to December 2022 were selected and randomly divided into two groups (41 in each group) by random number table method. Both groups were treated with straight wire arch orthodontic technology, and the anterior teeth were supported by micro-implant screws (micro-implant screw group) and flat guide plates (flat guide plate group), respectively.

View Article and Find Full Text PDF

Introduction: This study aimed to determine whether prescribed molar intrusion, with or without virtual occlusal bite-blocks (BB), resulted in actual molar intrusion and assisted with anterior open bite (AOB) correction in adult patients treated with Invisalign clear aligners (Align Technology, Santa Clara, Calif).

Methods: A retrospective study was conducted with 36 adult patients with AOB. Subjects were divided into 2 treatment groups: planned molar intrusion (PMI) and no-PMI (No-PMI).

View Article and Find Full Text PDF

Deep learning-designed implant-supported posterior crowns: Assessing time efficiency, tooth morphology, emergence profile, occlusion, and proximal contacts.

J Dent

August 2024

Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland; Division of Gerodontology and Removable Prosthodontics, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland.

Objectives: To compare implant supported crowns (ISCs) designed using deep learning (DL) software with those designed by a technician using conventional computer-aided design software.

Methods: Twenty resin-based partially edentulous casts (maxillary and mandibular) used for fabricating ISCs were evaluated retrospectively. ISCs were designed using a DL-based method with no modification of the as-generated outcome (DB), a DL-based method with further optimization by a dental technician (DM), and a conventional computer-aided design method by a technician (NC).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!