This study aims to quantify by intravital microscopy and histological wound scoring the effect of radial pressure wave treatment (RPWT) on murine incisional wound healing. The dorsal skinfold chamber in mice was used for intravital microscopy, whereby an incisional wound was created within the chamber. RPWT to the wound was carried out using a ballistic pressure wave source (EMS Swiss DolorClast). Animals received a dose of 500 pulses at an energy flux rate of 0.1mJ/mm(2) and a frequency of 3Hz at day 1, 3, 5, 7, 9, and 11 post wounding. RPW treated and untreated ApoE depleted mice (ApoE(-/-)) were compared to normal healing wild type animals (WT). The microcirculation of the wound was analyzed quantitatively in vivo using epi-illumination intravital fluorescence microscopy. Tissue samples were examined ex vivo for wound scoring and immunohistochemistry. Upon RPWT total wound score in ApoE(-/-) mice was increased by 13% (not significant) on day 3, by 37% on day 7 (P<0.05), and by 39% on day 13 (P<0.05) when compared to untreated ApoE(-/-) mice. Improved wound healing was associated with an increase of functional angiogenetic density by 23% (not significant) on day 5, by 36% on day 7 (P<0.05), and by 41% on day 9 (P<0.05). Following RPWT, on day three we observed enhanced expression of capase-3 (2-fold), proliferating cell nuclear antibody (PCNA, 1,6-fold), and endothelial nitric oxide synthase (eNOS, 2.6-fold), all P<0.05. In conclusion repetitive RPWT accelerated wound healing in ApoE(-/-) mice by increasing functional neovascular density. In addition our findings strongly suggest that RPW may facilitate the linear progression of wound healing phases by fostering apoptosis.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.mvr.2012.03.006 | DOI Listing |
Br J Anaesth
January 2025
Faculté de Médecine Paris-Saclay, Université Paris-Saclay, Le Kremlin-Bicêtre, Paris, France.
Micromachines (Basel)
December 2024
Mechatronics Engineering Department, Istanbul Ticaret University, 34854 Maltepe, Turkey.
An automated micro-tweezers system with a flexible workspace would benefit the intelligent sorting of live cells. Such micro-tweezers could employ a forced vortex strong enough to capture a single cell. Furthermore, addressable control of the position to the vortex would constitute a robotic system.
View Article and Find Full Text PDFNanomaterials (Basel)
January 2025
Institute of High Pressure Physics, Polish Academy of Sciences, Sokolowska 29/37, 01-142 Warsaw, Poland.
In situ X-ray reciprocal space mapping was performed during the interval heating and cooling of InGaN/GaN quantum wells (QWs) grown via metal-organic vapor phase epitaxy (MOVPE). Our detailed in situ X-ray analysis enabled us to track changes in the peak intensities and radial and angular broadenings of the reflection. By simulating the radial diffraction profiles recorded during the thermal cycle treatment, we demonstrate the presence of indium concentration distributions (ICDs) in the different QWs of the heterostructure (1.
View Article and Find Full Text PDFPediatr Cardiol
January 2025
Echocardiography Laboratory, Instituto Dante Pazzanese de Cardiologia, São Paulo, Brazil.
This study aimed to evaluate the hemodynamic and ventricular performance of neonates with hypoxic-ischemic encephalopathy (HIE) undergoing therapeutic hypothermia using conventional and advanced echocardiographic techniques. This observational, prospective study included 22 neonates with HIE matched with 22 healthy neonates. Echocardiographic studies were performed 24 h after achieving target temperature during hypothermia and 24 h after rewarming.
View Article and Find Full Text PDFJ Physiol Sci
January 2025
Department of Biomedical Engineering, Toyo University, Kawagoe, Japan.
The purpose of this study was to clarify sex differences in the inhibition of sympathetic vasomotor outflow which is caused by the loading of cardiopulmonary baroreceptors. Ten young males and ten age-matched females participated. The participants underwent a passive leg raising (PLR) test wherein they were positioned supine (baseline, 0º), and their lower limbs were lifted passively at 10º, 20º, 30º, and 40º.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!