A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Gaussian process models of dynamic PET for functional volume definition in radiation oncology. | LitMetric

Gaussian process models of dynamic PET for functional volume definition in radiation oncology.

IEEE Trans Med Imaging

Turku PET Centre and Department of Oncology and Radiotherapy, Turku University Hospital, 20521 Turku, Finland.

Published: August 2012

In routine oncologic positron emission tomography (PET), dynamic information is discarded by time-averaging the signal to produce static images of the "standardised uptake value" (SUV). Defining functional volumes of interest (VOIs) in terms of SUV is flawed, as values are affected by confounding factors and the chosen time window, and SUV images are not sensitive to functional heterogeneity of pathological tissues. Also, SUV iso-contours are highly affected by the choice of threshold and no threshold, or other SUV-based segmentation method, is universally accepted for a given VOI type. Gaussian Process (GP) time series models describe macro-scale dynamic behavior arising from countless interacting micro-scale processes, as is the case for PET signals from heterogeneous tissue. We use GPs to model time-activity curves (TACs) from dynamic PET and to define functional volumes for PET oncology. Probabilistic methods of tissue discrimination are presented along with novel contouring methods for functional VOI segmentation. We demonstrate the value of GP models for voxel classification and VOI contouring of diseased and metastatic tissues with functional heterogeneity in prostate PET. Classification experiments reveal superior sensitivity and specificity over SUV calculation and a TAC-based method proposed in recent literature. Contouring experiments reveal differences in shape between gold-standard and GP VOIs and correlation with kinetic models shows that the novel VOIs contain extra clinically relevant information compared to SUVs alone. We conclude that the proposed models offer a principled data analysis technique that improves on SUVs for oncologic VOI definition. Continuing research will generalize GP models for different oncology tracers and imaging protocols with the ultimate goal of clinical use including treatment planning.

Download full-text PDF

Source
http://dx.doi.org/10.1109/TMI.2012.2193896DOI Listing

Publication Analysis

Top Keywords

gaussian process
8
dynamic pet
8
functional volumes
8
functional heterogeneity
8
experiments reveal
8
models
6
pet
6
functional
6
suv
5
process models
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!