A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Impact of ablation catheter irrigation design on silent cerebral embolism after radiofrequency catheter ablation of atrial fibrillation: results from a pilot study. | LitMetric

Introduction: Silent cerebral lesions (SCL) are a sensitive tool to evaluate thromboembolic risk of catheter ablation. Recent data showed the possibility to reduce thrombus formation when the electrode-tissue interface cooling is optimized by a homogeneous flushing of saline along the entire surface of the distal electrode through a larger number of irrigation holes. The study aim is to compare procedural parameters and safety of pulmonary vein isolation (PVI) performed by using open-irrigated catheters with different irrigation design.

Methods And Results: Eighty patients (74% males; age 57 ± 12 years) with paroxysmal AF randomly underwent PVI performed with a new irrigation design catheter (group A, 40 patients) versus a standard irrigated catheter (group B, 40 patients). A cerebral magnetic resonance imaging (MRI) was performed before and after the procedure. Postprocedural brain MRI unveiled SCL in 2 patients in group A and in 3 in group B (5% vs 7.5%, P = 0.500). Intraprocedural ACT was the only independent factor associated with the occurrence of SCL (OR = 0.996; 95% CI 0.994-0.998, P < 0.001). Among procedural parameters, we observed a reduction of irrigation saline volume of 662 mL in group A versus group B (P < 0.001).

Conclusion: PVI performed with a new irrigated catheter did not reduce significantly the SCL risk when compared to a standard irrigated catheter. Intraprocedural ACT reduces the SCL risk of 0.4% for each point of ACT increase. For ACT > 320 seconds no SCL occurred. Finally, compared to a standard irrigated catheter, PVI performed with a new irrigation design catheter reduces significantly saline volume infusion.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1540-8167.2012.02298.xDOI Listing

Publication Analysis

Top Keywords

pvi performed
16
irrigated catheter
16
irrigation design
12
standard irrigated
12
catheter
9
silent cerebral
8
catheter ablation
8
procedural parameters
8
performed irrigation
8
design catheter
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!