Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background And Objectives: Implantable cardioverter defibrillator (ICD) therapy is recommended as the primary tool for prevention of sudden cardiac death (SCD) in symptomatic patients with severe left ventricular dysfunction. There is a paucity of information on whether this recommendation is appropriate for the Korean population with severe heart failure.
Subjects And Methods: The study group consisted of 275 consecutive patients (mean age 65 years, 71% male) who met the ICD implantation criteria for primary prevention (left ventricular ejection fraction ≤30% and New York Heart Association functional class II or III). We analyzed the clinical characteristics and outcomes of an ischemic cardiomyopathy (ICMP) group (n=131) and a non-ischemic cardiomyopathy (NICMP) group (n=144). The outcomes of these 2 groups were compared with the Multicenter Automatic Defibrillator Implantation Trial II (MADIT-II) conventional and Defibrillators in the Non-ischemic Cardiomyopathy Treatment Evaluation (DEFINITE) standard therapy groups, respectively.
Results: Eighty patients (29%) died during a follow-up period of 40±17 months. The NICMP group had better all-cause mortality rates than the ICMP group (19% vs. 40%, p<0.001), however both groups had a similar incidence of SCD (7% vs. 10%, p=0.272). The 2-year all-cause mortality and SCD for the ICMP group were similar to those of the MADIT-II conventional therapy group (20% vs. 20%, 7% vs. 10%, respectively, all p>0.05). All-cause mortality and the incidence of SCD in the NICMP group were comparable to those of the DEFINITE standard therapy group (13% vs. 17%, 6% vs. 6%, respectively, all p>0.05).
Conclusion: Korean patients with severe heart failure in both the ICMP and NICMP groups had all-caused mortality and risk of SCD comparable to patients in the MADIT-II and DEFINITE standard therapy groups. Therefore, the primary prevention criteria for ICD implantation would be appropriate in both Korean ICMP and NICMP patients.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3318089 | PMC |
http://dx.doi.org/10.4070/kcj.2012.42.3.173 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!