Unlabelled: In myocardial perfusion SPECT, transient ischemic dilation ratio (TID) is a well-established marker of severe ischemia and adverse outcome. However, its role in the setting of (82)Rb PET is less well defined.

Methods: We analyzed 265 subjects who underwent clinical rest-dipyridamole (82)Rb PET/CT. Sixty-two subjects without a prior history of cardiac disease and with a normal myocardial perfusion study had either a low or a very low pretest likelihood of coronary artery disease or negative CT angiography. These subjects were used to establish a reference range of TID. In the remaining 203 patients with an intermediate or high pretest likelihood, subgroups with normal and abnormal TID were established and compared with respect to clinical variables, perfusion defect scores, left ventricular function, and absolute myocardial flow reserve. Follow-up was obtained for 969 ± 328 d to determine mortality by review of the social security death index.

Results: In the reference group, TID ratio was 0.98 ± 0.06. Accordingly, a threshold for abnormal TID was set at greater than 1.13 (0.98 + 2.5 SDs). In the study group, 19 of 203 patients (9%) had an elevated TID ratio. Significant differences between subgroups with normal and abnormal TID ratio were observed for ejection fraction reserve (5.0 ± 6.4 vs. 1.8 ± 7.9; P < 0.05), difference between end-systolic volume (ESV) at rest and stress (ΔESV[stress-rest]; 1.8 ± 7.4 vs. 12.3 ± 13.0 mL; P < 0.0001), difference between end-diastolic volume (EDV) at rest and stress (ΔEDV[stress-rest]; 10.8 ± 11.5 vs. 23.8 ± 14.6 mL; P < 0.0001), summed rest score (1.8 ± 3.8 vs. 3.8 ± 7.6; P < 0.05), summed stress score (3.0 ± 5.4 vs. 7.5 ± 9.8; P < 0.002), summed difference score (1.3 ± 2.6 vs. 3.7 ± 5.3; P < 0.02), and global myocardial flow reserve (2.1 ± 0.8 vs. 1.7 ± 0.6; P < 0.02). Additionally, TID-positive patients had a significantly lower overall survival probability (P < 0.05). In a subgroup analysis of patients without regional perfusion abnormalities, TID-positive patients' overall survival probability was significantly smaller (P < 0.03), and TID was an independent predictor (exponentiation of the B coefficients [Exp(b)] = 6.22; P < 0.009) together with an ejection fraction below 45% (Exp[b] = 6.16; P < 0.002).

Conclusion: The present study suggests a reference range of TID for (82)Rb PET myocardial perfusion imaging that is in the range of previously established values for SPECT. Abnormal TID in (82)Rb PET is associated with more extensive left ventricular dysfunction, ischemic compromise, and reduced global flow reserve. Preliminary outcome analysis suggests that TID-positive subjects have a lower overall survival probability.

Download full-text PDF

Source
http://dx.doi.org/10.2967/jnumed.111.097600DOI Listing

Publication Analysis

Top Keywords

82rb pet
16
myocardial perfusion
16
abnormal tid
16
flow reserve
12
tid ratio
12
survival probability
12
tid
10
transient ischemic
8
ischemic dilation
8
dilation ratio
8

Similar Publications

Background: The majority of functional ischemia tests in patients with suspected chronic coronary syndromes (CCS) yield normal results. Implementing gatekeepers for patient preselection, such as pretest probability (PTP) and/or coronary artery calcium score (CACS), could reduce the number of normal scan results, radiation exposure and costs. However, the efficacy and safety of these approaches remain unclear.

View Article and Find Full Text PDF

Importance: Long-term use of anabolic androgenic steroids (AASs) is associated with a high risk of left ventricular hypertrophy, heart failure with reduced systolic function, and early sudden death, with the mechanism of progression being understudied. Early and persistent impaired myocardial microcirculation could be of clinical importance and a potential underlying mechanism of frequent and early cardiac disease among individuals with AAS use and a future potential target for intervention.

Objective: To investigate coronary microcirculation by measuring myocardial flow reserve (MFR) in men with current and former AAS use compared with controls with no prior AAS use, using cardiac rubidium 82 (82Rb) positron emission tomography/computed tomography (PET/CT).

View Article and Find Full Text PDF

The impact of long axial field of view (LAFOV) PET on oncologic imaging.

Eur J Radiol

December 2024

King's College London & Guy's and St Thomas' PET Centre, School of Biomedical Engineering and Imaging Sciences, King's College, London SE1 7EH, UK. Electronic address:

The development of long axial field of view (LAFOV) positron emission tomography coupled with computed tomography (PET/CT) scanners might be considered the biggest step forward in PET imaging since it became a mainstream clinical modality. Despite increased capital and maintenance costs and data storage requirements, the improvement in image quality, significantly faster acquisition times and lower radiopharmaceutical administered activities, allow a high quality and more efficient clinical service. This step change in technology overcomes some of the limitations of standard short axial field of view scanners.

View Article and Find Full Text PDF

Noise-aware dynamic image denoising and positron range correction for Rubidium-82 cardiac PET imaging via self-supervision.

Med Image Anal

February 2025

Department of Biomedical Engineering, Yale University, USA; Department of Radiology and Biomedical Imaging, Yale University, USA. Electronic address:

Rubidium-82 (Rb) is a radioactive isotope widely used for cardiac PET imaging. Despite numerous benefits of Rb, there are several factors that limits its image quality and quantitative accuracy. First, the short half-life of Rb results in noisy dynamic frames.

View Article and Find Full Text PDF

Background: Transient ischemic dilation (TID) of the left ventricular (LV) cavity is considered a high-risk marker in patients with abnormal single photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI). Stress image acquisition with rubidium-82 (Rb) PET occurs at peak stress compared to 30-60 minutes post-stress with SPECT. We aimed to evaluate the prognostic value of TID in patients undergoing Rb PET MPI.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!