Pulse pressure variation (PPV) can be monitored several ways, but according to recent survey data it is most often visually estimated ("eyeballed") by practitioners. It is not known how accurate visual estimation of PPV is, or whether eyeballing of PPV in goal-directed fluid therapy studies may limit the ability to blind the control group to PPV value. The goal of this study was to test the accuracy of visual estimation of PPV. Using a simulator program designed by the authors that runs on a PC, 20 residents and 19 attendings were shown five arterial pressure waveforms each with different PPV values (range 1-30 %) moving at one of three sweep speeds (6.25, 12.5, or 25 mm/s) and asked to determine the PPV. There was a weak but significant relationship between true PPV and eyeball PPV (r (2) = 0.22; p < 0.01). The agreement between true PPV and eyeball PPV was 3.3 ± 8.7 %. The mean percent error was 122 %. The rate of correct response group classification was 65 %. Mean percent error was higher the faster the waveform sweep speed (130 % at 25 mm/s vs. 117 % at 6.25 mm/s), and correct responsiveness classification lower (58 % at 25 mm/s vs. 69 % at 6.25 mm/s). The results from this study show that eyeballing the arterial pressure waveform in order to evaluate pulse pressure variation is not accurate.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10877-012-9359-8DOI Listing

Publication Analysis

Top Keywords

visual estimation
12
pulse pressure
12
pressure variation
12
ppv
11
estimation ppv
8
arterial pressure
8
true ppv
8
ppv eyeball
8
eyeball ppv
8
percent error
8

Similar Publications

Intracellular dark endothelial spots detected using specular microscopy are associated with graft failure after Descemet's membrane endothelial keratoplasty.

Graefes Arch Clin Exp Ophthalmol

January 2025

Division of Ophthalmology, Department of Visual Sciences, Nihon University School of Medicine, 30-1 Oyaguchi-kamicho, Itabashi-ku, Tokyo, 173-8610, Japan.

Purpose: To investigate the correlation between intracellular dark endothelial spots (IDESs) detected by specular microscopy and the incidence of graft failure after Descemet's membrane endothelial keratoplasty (DMEK).

Methods: We reviewed 100 consecutive DMEK patients performed by a single surgeon at two centres between January 2015 and July 2022. Central corneal thickness was evaluated using anterior segment optical coherence tomography (SS-1000; Tomey, Aichi, Japan), and endothelial cell density was measured using specular microscopy.

View Article and Find Full Text PDF

Background: The dietary intake of hospitalised patients is often compromised during hospitalisation, which can be a causal factor for hospital malnutrition. This is considered a public health problem worldwide and is associated with an increased risk of other complications.

Objectives: Our objective was to determine the dietary intake of hospitalised individuals and if the prescribed diet influences it.

View Article and Find Full Text PDF

This paper aims to address the challenge of precise robotic grasping of molecular sieve drying bags during automated packaging by proposing a six-dimensional (6D) pose estimation method based on an red green blue-depth (RGB-D) camera. The method consists of three components: point cloud pre-segmentation, target extraction, and pose estimation. A minimum bounding box-based pre-segmentation method was designed to minimize the impact of packaging wrinkles and skirt curling.

View Article and Find Full Text PDF

Evaluating the Performance Characteristics of Pressure Monitoring Systems.

Sensors (Basel)

January 2025

Skin Sensing Research Group, School of Health Sciences, Faculty of Environmental and Life Sciences, University of Southampton, Southampton SO17 1HE, UK.

Measuring interface pressure is currently used in a variety of settings, e.g., automotive or clinical, to evaluate pressure distribution at support surface interfaces.

View Article and Find Full Text PDF

The quality of surface morphology can reflect the electrical performance of silver-based contacts. Existing research on the correlation of morphological-electrical performance is based solely on empirical models from traditional visual inspections and only considers the impact of visually observable macro-textural features on electrical performance. However, the influence of micro-textural features on electrical performance should not be overlooked.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!