A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Combining refractive error and uncorrected visual acuity to assess the effectiveness of refractive corneal surgery. | LitMetric

Residual refractive error and uncorrected visual acuity are two frequently measures used to assess the effectiveness of refractive corneal surgery. Nordan and colleagues have suggested a Visual Function Index which combines these two measures in one quantitative measure. This article presents a Visual Function Score for radial keratotomy which includes a set of qualitative categories (excellent, good, fair, poor) and specifies the clinical values for refractive error and visual acuity in each category. There was substantial agreement among ophthalmologists who reviewed the category definitions, and we think that the Visual Function Score improves our ability to objectively assess surgical outcome. Application of the score to the Prospective Evaluation of Radial Keratotomy (PERK) Study data yielded closer agreement with refractive error results than with visual acuity values. The Visual Function Score lowered the classification of eyes that were hyperopic but had sufficient accommodation to overcome so that a high visual acuity result could be achieved. The inclusion of astigmatism values would be an important next step in the development of composite measures for the assessment of refractive surgery. In the future, a multifactorial index or score may be used to estimate the outcome of reported surgical procedures.

Download full-text PDF

Source

Publication Analysis

Top Keywords

visual acuity
20
refractive error
16
visual function
16
function score
12
visual
9
error uncorrected
8
uncorrected visual
8
assess effectiveness
8
effectiveness refractive
8
refractive corneal
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!