The magnetic behavior at room temperature of maghemite nanoparticles of variable sizes (from 7 to 20 nm) is compared using a conventional super quantum interference device (SQUID) and a recently patented technology, called MIAplex. The SQUID usually measures the magnetic response versus an applied magnetic field in a quasi-static mode until high field values (from -4000 to 4000 kA m(-1)) to determine the field-dependence and saturation magnetization of the sample. The MIAplex is a handheld portable device that measures a signal corresponding to the second derivative of the magnetization around zero field (between -15 and 15 kA m(-1)). In this paper, the magnetic response of the size series is correlated, both in diluted and powder form, between the SQUID and MIAplex. The SQUID curves are measured at room temperature in two magnetic field ranges from -4000 to 4000 kA m(-1) (-5T to 5T) and from -15 to 15 kA m(-1). Nonlinear behavior at weak fields is highlighted and the magnetic curves for diluted solutions evolve from quasi-paramagnetic to superparamagnetic behavior when the size of the nanoparticles increases. For the 7-nm sample, the fit of the magnetization with the Langevin model weighted with log-normal distribution corresponds closely to the magnetic size. This confirms the accuracy of the model of non-interacting superparamagnetic particles with a magnetically frustrated surface layer of about 0.5 nm thickness. For the other samples (10-nm to 21-nm), the experimental weak-field magnetization curves are modeled by more than one population of magnetically responding species. This behavior is consistent with a chemically uniform but magnetically distinct structure composed of a core and a magnetically active nanoparticle canted shell. Accordingly the weak-field signature corresponds to the total assembly of the nanoparticles. The impact of size polydispersity is also discussed.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/smll.201102660 | DOI Listing |
Biomed Phys Eng Express
January 2025
Children's Hospital of Eastern Switzerland, Claudiusstrasse 6, St.Gallen, 9006, SWITZERLAND.
Mapping the myomagnetic field of a straight and easily accessible muscle after electrical stimulation using triaxial optically pumped magnetometers (OPMs) to assess potential benefits for magnetomyography (MMG). Approach: Six triaxial OPMs were arranged in two rows with three sensors each along the abductor digiti minimi (ADM) muscle. The upper row of sensors was inclined by 45° with respect to the lower row and all sensors were aligned closely to the skin surface without direct contact.
View Article and Find Full Text PDFBiomed Phys Eng Express
January 2025
Biomedical Engineering , University of Wisconsin-Milwaukee College of Engineering and Applied Science, 3203 N Downer Ave, Milwaukee, Milwaukee, Wisconsin, 53211-3029, UNITED STATES.
Capacitive-based radiofrequency (Rf) radiation at 27 MHz offers a non-invasive approach for inducing hyperthermia, making it a promising technique for thermal cancer therapy applications. To achieve focused and site-specific hyperthermia, external material is required that efficiently convert Rf radiation into localized heat. Nanomaterials capable of absorbing Rf energy and convert into heat for targeted ablation are of critical importance.
View Article and Find Full Text PDFJ Neurosurg Case Lessons
January 2025
Department of Neurosurgery, Faculty of Medicine, Azad Tehran University of Medical Sciences, Tehran, Iran.
Background: Pedicle screw insertion in posterior spinal surgery can cause vascular injuries, including rare intercostal artery pseudoaneurysms, which are typically discovered incidentally during reimaging. Onyx embolization is an effective treatment for small artery pseudoaneurysms.
Observations: A 36-year-old man who had initially presented with back pain that remained unresponsive to nonsteroidal anti-inflammatory drugs was diagnosed with a T7-8 sarcomatous lesion confirmed by magnetic resonance imaging and biopsy.
Acta Orthop Belg
December 2024
Percutaneous intra-meniscal platelet-rich plasma (PRP) is a promising tool for managing low-grade meniscal injuries in non-athletic patients. The study evaluates the clinical and radiological outcomes of PRP intra-meniscal injection in meniscal tears. Forty-eight patients were injected with 3 injections of PRP at an interval of one week with a standardised technique under sonographic guidance.
View Article and Find Full Text PDFSurg Technol Int
January 2025
Department of Psychiatry and Narcology, I.M. Sechenov First Moscow State Medical University (Sechenov University), Moscow, Russian Federation.
Pelvic Venous Disorder (PEVD) and May-Thurner syndrome (MTS) represent relatively understudied vascular issues that can significantly impact patients' quality of life. This study aims to evaluate the efficacy of surgical treatment for PEVD and MTS, conduct a comparative analysis of outcomes, and determine the practical significance of different therapeutic approaches. The study was conducted from 2019 to 2022 in Moscow, Russia, encompassing two outpatient clinics.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!