Accurate intima-media thickness (IMT) measurement of the carotid artery from minimal plaque ultrasound images is a relevant clinical need, since IMT increase is related to the progression of atherosclerosis. In this paper, we describe a novel dual snake-based model for the high-performance carotid IMT measurement, called Carotid Measurement Using Dual Snakes (CMUDS). Snakes (which are deformable contours) adapt to the lumen-intima (LI) and media-adventitia (MA) interfaces, thus enabling the IMT computation as distance between the LI and MA snakes. However, traditional snakes might be unable to maintain a correct distance and in some spatial location along the artery, it might even collapse between them or diverge. The technical improvement of this work is the definition of a dual snake-based constrained system, which prevents the LI and MA snakes from collapsing or bleeding, thus optimizing the IMT estimation. The CMUDS system consists of two parametric models automatically initialized using the far adventitia border which we automatically traced by using a previously developed multi-resolution approach. The dual snakes evolve simultaneously and are constrained by the distances between them, ensuring the regularization of LI/MA topology. We benchmarked our automated CMUDS with the previous conventional semi-automated snake system called Carotid Measurement Using Single Snake (CMUSS). Two independent readers manually traced the LIMA boundaries of a multi-institutional, multi-ethnic, and multi-scanner database of 665 CCA longitudinal 2D images. We evaluated our system performance by comparing it with the gold standard as traced by clinical readers. CMUDS and CMUSS correctly processed 100% of the 665 images. Comparing the performance with respect to the two readers, our automatically measured IMT was on average very close to that of the two readers (IMT measurement biases for CMUSS was equal to -0.011±0.329mm and -0.045±0.317mm, respectively, while for CMUDS, it was 0.030±0.284mm and -0.004±0.273mm, respectively). The Figure-of-Merit of the system was 98.5% and 94.4% for CMUSS, while 96.0% and 99.6% for CMUDS, respectively. Results showed that the dual-snake system CMUDS reduced the IMT measurement error accuracy (Wilcoxon, p<0.02) and the IMT error variability (Fisher, p<3×10(-2)). We propose the CMUDS technique for use in large multi-centric studies, where the need for a standard, accurate, and automated IMT measurement technique is required.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.ultras.2012.03.005 | DOI Listing |
J Clin Med
January 2025
Department of Internal Medicine, Angiology, and Physical Medicine, Faculty of Medical Sciences in Zabrze, Medical University of Silesia, Batorego 15 St., 41-902 Bytom, Poland.
The interrelationship of thyroid volume and function with features of cardiovascular dysfunction has already been investigated but some aspects remain unclear, especially in terms of subclinical cardiovascular dysfunction in euthyroid patients. Intima-media thickness (IMT) measurement in ultrasound B-mode imaging in different vascular beds (most frequently within the common carotid artery) is one of the most important tools for the detection of subclinical atherosclerosis in both clinical practice and research. This article aimed to present the results of our research on the association between the thyroid evaluation parameters and the IMT measured in both the carotid and femoral arteries in euthyroid patients aged 18 to 65 years taking into account the influence of diabetes, hypertension, and excess body mass.
View Article and Find Full Text PDFSports (Basel)
January 2025
DMeM, University of Montpellier, INRAE, 34000 Montpellier, France.
Background: Objective training load (TL) indexes used in resistance training lack physiological significance. This study was aimed to provide a muscle physiology-based approach for quantifying TL in resistance exercises (REs).
Methods: Following individual torque-velocity profiling, fifteen participants (11 healthy males, stature: 178.
Eur J Pharm Sci
January 2025
RAPSODEE, IMT Mines Albi, CNRS, University of Toulouse, 81013 Albi, France.
This study investigates the effects of disintegrants sodium starch glycolate (SSG) and crospovidone (CP) on the printability, rheological properties, and disintegration time of agar and hydroxypropyl methylcellulose (HPMC)-based formulations designed for semi-solid extrusion. Printability was assessed by measuring the dimensional accuracy of manually extruded filaments. Rheological analysis was performed using oscillatory measurements.
View Article and Find Full Text PDFAust Crit Care
January 2025
KU Leuven, Department of Rehabilitation Sciences, Research Group for Rehabilitation in Internal Disorders, B-3000, Leuven, Belgium; University Hospitals Leuven, Department of Intensive Care Medicine, Leuven, Belgium.
Background: Recent studies suggest that fast and deep inspirations against either low or high external loads may provide patients with weaning difficulties with a training stimulus during inspiratory muscle training (IMT). However, the relationship between external IMT load, reflected by changes in airway pressure swings (ΔPaw), and total inspiratory effort, measured by oesophageal pressure swings (ΔPes), remains unexplored. Additionally, the association between ΔPes, ΔPaw, and inspiratory muscle activations remains unclear.
View Article and Find Full Text PDFAm J Cardiovasc Dis
December 2024
Department of Cardiovascular Surgery, School of Medicine, Shahid Modarres Hospital, Shahid Beheshti University of Medical Sciences Tehran, Iran.
Objectives: Postoperative pulmonary complications (POPC) are common after cardiac surgeries such as coronary artery bypass grafting (CABG) and are influenced by factors including anesthesia and surgical trauma. Inspiratory muscle training (IMT) with visual biofeedback may mitigate these complications. This study investigates the impact of threshold loading inspiratory muscle training (TL-IMT) combined with respiratory biofeedback on the dynamic strength of inspiratory muscles (S-index) in patients undergoing CABG surgery during their hospitalization phase.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!