Background Context: The biomechanical fixation strength afforded by pedicle screws has been strongly correlated with bone mineral density. It has been postulated that "hubbing" the head of the pedicle screw against the dorsal laminar cortex provides a load-sharing effect, thereby limiting cephalocaudad toggling and improving the pullout resistance of the pedicle screw.

Purpose: To evaluate the pullout strength (POS) of monoaxial hubbed pedicle screws versus standard fixation in the thoracic spine.

Study Design: Biomechanical investigation.

Methods: Twenty-two human cadaveric thoracic vertebrae were acquired and dual-energy X-ray absorptiometry scanned. Osteoporotic (n = 16) and normal (n = 6) specimens were instrumented with a 5.0 × 35-mm pedicle screw on one side in a standard fashion. In the contralateral pedicle, 5.0 × 30-mm screw was inserted with hubbing of the screw into the dorsal lamina. A difference in screw length was used to achieve equivalent depth of insertion. After 2,000 cycles of cephalocaudad toggling, screws were pulled out with the tensile force oriented to the midline of the spine and peak POS measured in newtons (N). Four additional specimens were subjected to microcomputed tomography (micro-CT) analysis to evaluate internal pedicle architecture after screw insertion.

Results: Hubbed screws resulted in significantly lower POS (290.5 ± 142.4 N) compared with standard pedicle screws (511.5 ± 242.8 N; p = .00). This finding was evident in both normal and osteoporotic vertebrae based on independent subgroup post hoc analyses (p<.05). As a result of hubbing, half of the specimens fractured through the lamina or superior articular facet (SAF). No fractures occurred on the control side. There was no difference in mean POS for hubbed screws with and without fracture; however, further micro-CT analysis revealed the presence of internal fracture propagation for those specimens that did not have any external signs of failure.

Conclusions: Hubbing pedicle screws results in significantly decreased POS compared with conventional pedicle screws. Hubbing predisposes toward iatrogenic fracture of the dorsal lamina, transverse process, or SAF during insertion.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.spinee.2012.03.020DOI Listing

Publication Analysis

Top Keywords

pedicle screw
12
pedicle screws
12
pullout resistance
8
pedicle
8
screw dorsal
8
cephalocaudad toggling
8
screw
7
screws
5
biomechanical pedicle
4
screw hubbing
4

Similar Publications

Introduction: The role of low-pathogenic bacteria cultured from removed spinal implants is unclear and the efficacy of perioperative single-dose antibiotics against such bacteria remains underexplored.

Research Question: This study aims to investigate whether pedicle screw loosening is associated with pathogens and if the choice of perioperative antibiotics can prevent these bacteria.

Methods: A retrospective analysis was conducted on 93 patients with implants removed between 01/01/2018 and 03/31/2020.

View Article and Find Full Text PDF

Objective: In the current study, to demonstrate the advantages of oblique lateral interbody fusion (OLIF), we focused on the therapeutics for lumbar spinal tuberculosis with the comparison of three treatments, including anterior approach, posterior approach, and OLIF combined with posterior percutaneous pedicle screw fixation.

Methods: This study included patients with lumbar spinal tuberculosis from July 2015 to June 2018. We divided these patients into three groups: 35 patients underwent an anterior-only approach (Group A), 36 patients underwent a posterior-only approach (Group B), and 31 patients underwent OLIF combined with posterior percutaneous pedicle screw fixation (Group C).

View Article and Find Full Text PDF

Objective: This study aims to explore the predictive value of endplate morphology and pedicle screw bone quality score on screw loosening after single-level lumbar spinal fusion surgery.

Methods: A retrospective analysis was conducted on the clinical data of 207 patients who underwent single-level lumbar spinal fusion (34 in the screw loosening group and 173 in the non-screw loosening group). Univariate analysis and binary logistic regression model analysis were performed using SPSS 27.

View Article and Find Full Text PDF

Applying a three-dimensional curved lumbar spine model to simulate surgery for training residents in pedicle screw insertion.

Surg Radiol Anat

December 2024

Department of Anatomy, Digital Imaging and 3D Modelling Laboratory, Faculty of Medicine, Ege University, Bornova, 35100, Izmir, Turkey.

Purpose: The challenges of spinal surgery can be overcome by deeply understanding the anatomical and surgical complexities of the region through the use of model simulators. This study investigates the impact of digitally designed simulators, specifically lumbar spinal models with abnormal curvature, on preoperative planning and their effectiveness as training tools. The study addresses challenges in spine surgery, such as unique deformities, classification issues, and associated abdominal structure abnormalities.

View Article and Find Full Text PDF

Objective: To present the clinical result of spinal fixation system made entirely of Carbon-Fiber-Reinforced (CFR)-Hybrid Polyaryl-Ether-Ether-Ketone (PEEK).

Summary Of Background Data: Fusion surgery has been used to treat chronic low back pain caused by degenerative disk disease (DDD). The traditional pedicle screw system made of titanium, though biocompatible, can lead to complications, such as stress shielding and implant failure.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!