Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
A quantitative bioanalytical assay for cediranib and its N(+)-glucuronide metabolite was developed and validated. Human plasma samples were pre-treated using protein precipitation with acetonitrile containing erlotinib and CYT-387 as internal standards for the glucuronide metabolite and parent compound, respectively. The extract was diluted with water and injected into the chromatographic system. This system consisted of sub-2 μm particles, a trifunctional bonded octadecyl silica column with gradient elution using 0.005% (v/v) of formic acid in a mixture of water and methanol. The eluate was transferred into the electrospray interface with positive ionization and the analytes were detected in the selected reaction monitoring mode of a triple quadrupole mass spectrometer. The assay was validated in a 1-290 ng/ml calibration range for cediranib and 0.2-52 ng/ml for its glucuronide metabolite. The lowest levels of these ranges corresponded to the lower limits of quantification for both compounds. Within day precisions were 4.0-6.7% for cediranib and 4.1-11.9% for its glucuronide, between day precisions were 4.2-10.2 and 4.8-14.4% and accuracies were between 99 and 106 and 84 and 94% for cediranib and its metabolite, respectively. Stabilities of both compounds were sufficient under all relevant conditions. Finally, the assay was successfully used to assess drug levels in a pharmacokinetic mouse study.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jchromb.2012.03.020 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!