We report a case of torsade de pointes after intravenous amiodarone and concurrent hypokalemia. Despite treatment cessation and correction of electrolyte abnormalities, excessive QTc prolongation was noted, which persisted for 14 days. This prolonged course for QTc normalization may be attributed to the high rate of amiodarone loading and concurrent electrolyte disturbances coupled with possible underlying individual variability in pharmacokinetics.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3303706PMC
http://dx.doi.org/10.1155/2012/673019DOI Listing

Publication Analysis

Top Keywords

torsade pointes
8
qtc prolongation
8
intravenous amiodarone
8
pointes persistent
4
persistent qtc
4
prolongation intravenous
4
amiodarone report
4
report case
4
case torsade
4
pointes intravenous
4

Similar Publications

Introduction: Medical simulation education has expanded in the remote learning sphere, providing educational opportunities to under-resourced areas and the ability to engage learners limited by time or geographic location. Pediatric resuscitation training has historically been in-person relying on Pediatric Advanced Life Support (PALS) algorithms, yet many pediatric providers are often faced with treating adult or adult-sized patients. Our goal was to develop a tele-simulation remote learning module highlighting possible diagnoses and scenarios that require adult treatment-minded approaches for the pediatric clinician, including the use of Advanced Cardiac Life Support (ACLS) algorithms.

View Article and Find Full Text PDF

Extended Rhythm Monitoring to Assess for Ventricular Arrhythmias After Transcatheter Pulmonary Valve Replacement With the Harmony Valve.

Circ Cardiovasc Interv

December 2024

Department of Pediatrics, Pediatric Cardiology, Stanford University, Palo Alto, CA. (J.K.Y., L.W., A.C.T., H.C., A.W.R., L.F.P., S.R.C., A.M.D., D.B.M.).

Background: Varying rates of nonsustained ventricular tachycardia (NSVT) have been reported early after transcatheter pulmonary valve replacement (TPVR) with the Harmony valve, but data regarding rhythm outcomes beyond hospital discharge are limited. This study aims to characterize ventricular arrhythmias after Harmony TPVR from implant through mid-term follow-up.

Methods: Ventricular arrhythmia data from postimplant telemetry and follow-up extended rhythm monitoring (ERM) were analyzed after Harmony TPVR.

View Article and Find Full Text PDF

Background: This case highlights the management of concomitant acute myocarditis and congenital long QT syndrome with electrical storm and incessant Torsade de Pointes.

Case Presentation: An 18 years-old Southeast Asian para 1 abortus 0 (P1A0) postpartum patient with cesarean section owing to severe preeclampsia, acute lymphocytic myocarditis, and prolonged QT interval owing to long QT syndrome. She has incessant Torsade de Pointes treated with beta-blocker, lidocaine, overdrive pacing with a temporary transvenous pacemaker, left cardiac sympathetic denervation per video-assisted thoracoscopic surgery, and implantable cardioverter-defibrillator implantation.

View Article and Find Full Text PDF

Nitazene opioids and the heart: Identification of a cardiac ion channel target for illicit nitazene opioids.

J Mol Cell Cardiol Plus

December 2024

School of Physiology, Pharmacology and Neuroscience, Biomedical Sciences Building, University Walk, Bristol BS8 1TD, UK.

The growing use of nitazene synthetic opioids heralds a new phase of the opioid crisis. However, limited information exists on the toxic effects of these drugs, aside from a propensity for respiratory depression. With restricted research availability of nitazenes, we used machine-learning-based tools to evaluate five nitazene compounds' interaction potential with the hERG potassium channel, a key drug antitarget in the heart.

View Article and Find Full Text PDF

Introduction: A healthy young woman, age 26 without prior cardiac complications, experienced an out-of-hospital cardiac arrest caused by ventricular fibrillation (VF), which coincided with a fever. Comprehensive diagnostics including echo, CMR, exercise testing, and genetic sequencing, did not identify any potential cause. This led to the diagnosis of idiopathic VF and installment of an implantable cardioverter defibrillator, which six months later appropriately intervened another VF episode under conditions comparable to the first event.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!