A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Double-bundle anterior cruciate ligament reconstruction using bone-patellar tendon-bone allograft: technique and 2- to 5-year follow-up. | LitMetric

Background: Nonanatomic transtibial single-bundle anterior cruciate ligament reconstruction (SB-ACLR) with a bone-patellar tendon-bone (BPTB) allograft has been used for a long time and has shown the same satisfactory clinical results as an autograft; however, it has not been reported if a double-bundle ACLR (DB-ACLR) could be performed with a BPTB allograft and achieve even better results.

Hypothesis: The DB-ACLR with a BPTB allograft is technically feasible and will be superior to the SB technique in restoring better anterior and rotating stability.

Study Design: Cohort study; Level of evidence, 2.

Methods: The study was performed with 56 patients, and 52 (25 in the DB group and 27 in the SB group) of them were followed up at 2 to 5 years. With an irradiated deep-frozen BPTB allograft, a standard single-incision arthroscopic technique was used, and the graft was fixed with bioabsorbable interference screws on both the femoral and tibial sides. Outcome assessment at final follow-up included International Knee Documentation Committee (IKDC), Tegner, and Lysholm scores; side-to-side difference by conventional KT-2000 arthrometer; total anteroposterior (AP) laxity by the back-pushing KT-2000 arthrometer; pivot shift (0, +, ++); range of motion (ROM); and isokinetic muscle strength evaluation.

Results: Mean follow-up was 47.3 ± 11.5 and 58.2 ± 6.6 months for the DB group and SB group, respectively. A statistically significant difference in favor of the DB group was found with the total AP laxity at 30° (P < .05). The overall incidence of pivot shift in the DB group (4% ++) was significantly lower than that in the SB group (26%: 19% + and 7% ++; P = .029). No significant differences were found between the 2 groups in terms of IKDC score, Lysholm score, Tegner score, conventional KT-2000 arthrometer anterior laxity, ROM, and muscle strength.

Conclusion: A DB-ACLR with a BPTB allograft is feasible and achieved more satisfactory results than the transtibial SB technique in terms of total AP stability and rotational stability in spite of no significant differences among other clinical parameters.

Download full-text PDF

Source
http://dx.doi.org/10.1177/0363546512440686DOI Listing

Publication Analysis

Top Keywords

bptb allograft
20
kt-2000 arthrometer
12
anterior cruciate
8
cruciate ligament
8
ligament reconstruction
8
bone-patellar tendon-bone
8
db-aclr bptb
8
group group
8
conventional kt-2000
8
pivot shift
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!