A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

[Automatic continuous monitoring of volatile organic compounds using ion mobility spectrometer array]. | LitMetric

An ion mobility spectrometer array was designed, in order to broaden the detection range of ion mobility spectrometer and improve the accuracy of compound identification. This instrument was based on the combination of ionization sources of 63Ni positive ion mode, 63Ni negative ion mode and photoionization mode with vacuum UV lamp, and it can continuously monitor the volatile organic compounds in air. With the automatic system of sampling and injection of this instrument, the positive ion of dimethyl sulfoxide and negative ion of dichloromethane were detected simultaneously. By comprehensive analysis of spectra with ion mobility spectrometer array, acrylonitrile, m-xylene and acetone were identified, which were difficult to be distinguished under the 63Ni positive ion mode. Acetone samples were determined quantitatively within four days continuously, and the results indicated that the linear range of acetone in this instrument was 2 orders of magnitude. The linear correlation coefficient R was higher than 0.995, and the relative standard deviations were controlled in the range of 4.0%-18.3%. Methacrylate leaked in simulation was monitored on-line for 24 h continuously, using the method of dynamic tracking, and the result showed the leaking time and the concentration of methacrylate directly.

Download full-text PDF

Source

Publication Analysis

Top Keywords

ion mobility
16
mobility spectrometer
16
positive ion
12
ion mode
12
ion
9
volatile organic
8
organic compounds
8
spectrometer array
8
63ni positive
8
negative ion
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!