Is anterior cervical fusion with a porous tantalum implant a cost-effective method to treat cervical disc disease with radiculopathy?

Spine (Phila Pa 1976)

Department of Orthopaedic Surgery, Instituto de Cirugía Ortopédica y Traumatología de Barcelona, Barcelona, Spain.

Published: September 2012

Study Design: Retrospective cost-effectiveness analysis.

Objective: To determine the relative cost-effectiveness of anterior cervical discectomy with fusion (ACDF) using a porous tantalum implant compared with autograft with plating, for single-level cervical disc disease with radiculopathy.

Summary Of Background Data: ACDF with autograft as an interbody spacer is a generally accepted method to treat degenerated cervical discs with radiculopathy. Concerns about donor site morbidity and the structural characteristics of autograft stimulated investigations of alternative materials. Techniques may differ in their operative risks, complications, outcomes, and resource use.

Methods: A retrospective review of clinical outcomes and total cost of illness for 5 years postsurgery was performed for 61 consecutive patients enrolled for this study. Twenty-eight patients were treated with single-level ACDF using either a stand-alone, porous tantalum implant, without graft inside the implant, and 33 patients received autograft and plating. A cost-effectiveness analysis comparing the 2 ACDF treatment methods was conducted. This article reports clinical assessments, quality adjusted life years gained, and an incremental cost-effectiveness ratio analysis.

Results: Patients in both cohorts reported improved clinical outcomes, including neck disability index, visual analogue scale, Short-Form 36, Odom's clinical assessment, and patient satisfaction at 5 years postindex surgery. The mean cost of illness for the study period, including preoperative through 5 years postoperative assessments, was 6806 per patient treated with tantalum and 10,143 per patient receiving autograft and plate. Quality-adjusted life years (QALY) gained were 9.41 and 7.14 for the tantalum and control cohorts, respectively. The cost per QALY for the tantalum group was 723 and 1420 for the control group. The incremental cost-effectiveness ratio of ACDF with a porous tantalum implant compared with ACDF with autograft and plate was -1473 per patient per year for the duration of this study.

Conclusion: This cost-effectiveness analysis reports favorable results for ACDF procedures utilizing a tantalum implant. The data reported suggest that using porous tantalum as a stand-alone device is less costly and more effective than autograft and plate in ACDF procedures.

Download full-text PDF

Source
http://dx.doi.org/10.1097/BRS.0b013e318255a184DOI Listing

Publication Analysis

Top Keywords

porous tantalum
20
tantalum implant
20
autograft plate
12
tantalum
9
anterior cervical
8
method treat
8
cervical disc
8
disc disease
8
acdf
8
acdf porous
8

Similar Publications

This study investigates the deposition of tantalum (Ta) coatings on carbon foams using the chemical vapor deposition (CVD) method to enhance their compressive strength. Two types of open-cell carbon foams, CF-1 and CF-2, with different strut diameters, were examined. The morphology and uniformity of the coatings were characterized, and the effect of coating thickness on the compressive strength of the foams was systematically analyzed.

View Article and Find Full Text PDF

Bone defects are difficult to treat clinically and most often require bone grafting for repair. However, the source of autograft bone is limited, and allograft bone carries the risk of disease transmission and immune rejection. As tissue engineering technology advances, bone replacement materials are playing an increasingly important role in the treatment of bone defects.

View Article and Find Full Text PDF

Application of additive manufacturing TaBw01 porous tantalum rod in ARCO stage II osteonecrosis of the femoral head.

J Orthop Surg Res

December 2024

Center for Joint Surgery, Southwest Hospital, Army Medical University, Gaotanyan Street, Shapingba District, Chongqing, 400038, China.

Purpose: This study aims to investigate the suitable surgical strategies for applying TaBw01 porous tantalum rod across different stages of osteonecrosis of the femoral head (ONFH).

Methods: TaBw01 tantalum rods were fabricated using type FTaY-1 tantalum powder via the foam impregnation-sintering method. Mechanical testing with the Instron 8801 universal testing machine and finite element analysis (FEA) assessed single tantalum rod implantation and impaction bone grafting combined with rod implantation.

View Article and Find Full Text PDF

Anodic Oxide Films Grown in Dehydrated Phosphate/Glycerol Electrolytes at High Temperatures.

Langmuir

December 2024

Key Laboratory of Soft Chemistry and Functional Materials of Education Ministry, Nanjing University of Science and Technology, Nanjing 210094, China.

Traditional anodization was generally conducted in aqueous or water-containing solutions at room temperature or even lower temperatures. The two best known examples of the application of traditional anodization in the fabrication of nanostructured oxides are porous anodic alumina and titania nanotube films. In 1998, Melody et al.

View Article and Find Full Text PDF

Objective: To explore the surgical technique and clinical outcomes of biological total hip arthroplasty(THA) combined with impacting bone grafting for the treatment of moderate to severe acetabular invagination secondary to rheumatoid arthritis(RA).

Methods: Total of 20 patients(28 hips) with RA secondary to acetabular invagination were treated with THA of bioprosthesis combined with autogenous bone grafting from January 2012 to October 2020, including 5 males(8 hips) and 15 females(20 hips) with an average age of (55.10±4.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!