Lead in paint continues to be a threat to children's health in cities across the United States, which means there is an ongoing need for testing and analysis of paint. This ongoing analytical effort and especially development of new methods continue to drive the need for diagnostic testing materials that provide the analytical challenges of real-world paints. To this end, 31 different types of paint test materials were developed and prepared. Preparation of the materials included development of lead-containing paint films yielding an overall relative standard error for one individual test sample being less than 10%. The 31 diagnostic test materials prepared with these paint films included two lead pigments; lead concentrations from nominally 0 to 2.0 mg lead/cm(2) (0 to 5% lead by weight); overlayers of both "lead-free," oil-based and water-based paints; Al, Ba, and Mg as potential chemical interferents; red and black potential color interferents; and substrates of wood, metal, masonry, and plaster. These materials challenge each step in method development and evaluation, including paint sample collection and preparation, lead extraction, and measurement of solubilized lead. When the materials were used to test performance of a new lead-in-paint testing method based on extraction using a rotor/stator method and measurement using turbidimetry, the results agreed to within ±20% of the expected lead values for 30 out of 31 of the diagnostic test materials, thereby demonstrating their levels of quality and utility.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1039/c2em11004k | DOI Listing |
ACS Nano
January 2025
Clinical Translational Research Center of Aggregation-Induced Emission, The Second Affiliated Hospital, School of Medicine, School of Science and Engineering, Shenzhen Institute of Aggregate Science and Technology, The Chinese University of Hong Kong, Shenzhen (CUHK-Shenzhen), Shenzhen, Guangdong 518172, China.
A revolutionary transformation in biomedical imaging is unfolding with the advent of aggregation-induced emission luminogens (AIEgens). These cutting-edge molecules not only overcome the limitations of traditional fluorescent probes but also improve the boundaries of high-contrast imaging. Unlike conventional fluorophores suffering from aggregation-caused quenching, AIEgens exhibit enhanced luminescence when aggregated, enabling superior imaging performance.
View Article and Find Full Text PDFAbdom Radiol (NY)
January 2025
Department of Radiology, Shengli Clinical Medical College of Fujian Medical University, Fujian Provincial Hospital, Fuzhou University Affiliated Provincial Hospital, Fuzhou, China.
Objective: This study investigates the diagnostic value of Vesical Imaging Reporting and Data System (VI-RADS) in biparametric MRI (bp-MRI) for the detection of muscular infiltration in bladder cancer, and to investigate whether apparent diffusion coefficient (ADC) value can function as a potential indicator of bp-MRI VI-RADS for patient benefit.
Materials And Methods: This single-center retrospective study enrolled 81 patients with pathologically confirmed bladder cancer from October 2019 to November 2021. Two readers independently scored the T2-weighted images and diffusion-weighted images of each index lesion based on the VI-RADS criteria, subsequently deriving the bp-MRI VI-RADS scores.
Clin J Sport Med
January 2025
Sport, Exercise Medicine and Lifestyle Institute (SEMLI), Faculty of Healthy Sciences, University of Pretoria, Pretoria, South Africa.
Objective: To determine if any gradual onset running-related injury (GORRI) was associated with any allergies, multiple allergies (allergies to animals, plants, medication), and allergy medication use.
Design: Cross-sectional descriptive study.
Setting: Two Oceans Marathons (56 km, 21.
J Clin Microbiol
December 2024
National Cancer Institute, Rockville, Maryland, USA.
Unlabelled: Human papillomavirus (HPV) genotype predicts cervical cancer risk, and genotyping could help guide the management of HPV positives as part of cervical screening. An isothermal amplification HPV extended genotyping test (ScreenFire HPV RS assay) can assay up to 96 samples/controls in 1 hour plus preparation time. A novel format with pre-aliquoted reagents and an anti-contamination component (Zebra BioDome) could simplify the HPV testing process and reduce the chances of post-amplification contamination.
View Article and Find Full Text PDFNanoscale Horiz
January 2025
Ministry of Education Key Laboratory for the Green Preparation and Application of Functional Materials, Hubei University, Wuhan 430062, People's Republic of China.
Coordinating the droplet capture, transport, and shedding processes during fog collection to achieve efficient fog collection is a major challenge. In this study, a copper mesh with different wettability was prepared by chemical etching and thiol modification. The Cu(OH) needle structure on the surface of the samples was characterized by FE-SEM and EDS tests, and the surface of the samples was chemically analyzed by infrared and XPS analyses.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!