The highly sensitive and selective potentiometric biosensor for creatinine determination has been developed by us earlier. In it, pH-sensitive field effect transistors were used as transducer and immobilized creatinine deiminase (EC 3.5.4.21)--as a biosensitive element. In the work presented, we optimized this biosensor for creatinine analysis in real samples of dialysate in patients with renal failure. The optimized version of biosensor was applied for on-line monitoring of the level of creatinine in the patient's dialysate fluid in the course of dialysis session. High correlation between the biosensor analysis and traditional Jaffe method was demonstrated.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.bios.2012.02.062DOI Listing

Publication Analysis

Top Keywords

biosensor creatinine
8
biosensor
5
application creatinine-sensitive
4
creatinine-sensitive biosensor
4
biosensor hemodialysis
4
hemodialysis control
4
control highly
4
highly sensitive
4
sensitive selective
4
selective potentiometric
4

Similar Publications

A novel LC-MS/MS assay for low concentrations of creatinine in sweat and saliva to validate biosensors for continuous monitoring of renal function.

J Chromatogr B Analyt Technol Biomed Life Sci

December 2024

Clinical Laboratory, Catharina Hospital Eindhoven, Eindhoven 5623 EJ, The Netherlands; Department of Biomedical Engineering, Chemical Biology, Eindhoven University of Technology, Groene Loper 3, Eindhoven 5612 AE, The Netherlands.

Monitoring of kidney function traditionally relies on plasma creatinine concentrations, necessitating invasive blood draws. Non-invasively obtainable biofluids, such as sweat and saliva, present a patient-friendly alternative with potential for continuous monitoring. This study focusses on developing and validating a novel Liquid Chromatography- tandem Mass Spectrometry (LC-MS/MS) assay as a reference test for measuring low creatinine concentrations in sweat and saliva.

View Article and Find Full Text PDF

Fabrication of bio-mimic nanozyme based on Mxene@AuNPs and molecular imprinted poly(thionine) films for creatinine detection.

Biosens Bioelectron

March 2025

Department of Cogno-Mechatronics Engineering, College of Nanoscience and Nanotechnology, Pusan National University, Busan, 46241, Republic of Korea. Electronic address:

Creatinine (Ctn) is a biomarker for chronic kidney disease (CKD). In this study, a highly sensitive and specific detection method for Ctn based on a molecularly imprinted polymer (MIP) based electrochemical biosensor was developed. Mxene (Mx), which has high absorption properties, was modified using carbon screen-printed electrodes (SPCE).

View Article and Find Full Text PDF

Enzyme-free detection of creatinine as a kidney dysfunction biomarker using TiO flow-through membranes.

Nanoscale Adv

December 2024

Nanomaterials Research Group (NRG), Physics Division, PINSTECH Islamabad 44000 Pakistan

TiO nanotube flow-through membranes (TNTsM) were fabricated anodization of Ti foil and explored as a biosensing platform for creatinine detection. The electrodes were prepared in different configurations including TNT membrane with top surface up (TNTsMTU/TNPs/FTO), TNT membrane with bottom surface up (TNTsMBU/TNPs/FTO), TNT membrane with top surface up containing nanograss (TNTsMNG/TNPs/FTO), and TNTs/NPs/FTO and TiO nanoparticles (TNPs) film on fluorine doped tin oxide (TNPs/FTO). Electrochemical studies depict the higher electrochemical activity (sensitivity ∼19.

View Article and Find Full Text PDF

One-Step Electrochemical Modification of PEDOT:PSS/PBNPs Hybrid Hydrogel on the Screen-Printed Electrode Surface for Highly Sensitive Detection of Creatinine.

ACS Appl Mater Interfaces

December 2024

Biosensor National Special Laboratory, Key Laboratory of Biomedical Engineering of Ministry of Education, College of Biomedical Engineering and Instrument Science, Zhejiang University, Hangzhou, Zhejiang 310027, PR China.

Creatinine (CRE) is frequently measured in clinical practice due to its recognized significance as a pivotal biomarker across a spectrum of renal and cardiovascular disorders. However, the rapid and accurate detection of CRE for assessing kidney and muscle functions remains challenging. Here, we prepared the poly(3,4ethylenedioxythiophene):poly(styrenesulfonate) (PEDOT:PSS) hydrogel uniformly loaded with Prussian blue nanoparticles (PBNPs) via a one-step metal-assisted electrochemical modification method on the screen-printed electrode for ultrasensitive CRE detection.

View Article and Find Full Text PDF

Creatinine is indeed a crucial biomarker for kidney diseases. In this work, a novel electrochemical biosensor based on a copper-hemin metal organic framework [Cu-hemin metal-organic framework (MOF)] nanoflake decorated with palladium (Pd) (Pd/Cu-hemin MOF) was fabricated and incorporated with creatinine deiminase (CD) on a glassy carbon electrode (GCE) for creatinine detection. The formation of a Pd/Cu-hemin MOF composite was confirmed by X-ray photoelectron spectroscopy, X-ray diffraction, and Fourier transform infrared spectroscopy.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!