A simple, rapid, specific and precise reversed-phase high-performance liquid chromatographic method was developed for simultaneous estimation of triacetin, acetic ether, butyl acetate and amorolfine in marketed pharmaceutical liniment. Chromatographic separation was performed on a Shimadzu VP-ODS C(18) column using the mixture of citric acid-hydrochloric acid-sodium hydrate buffer (pH 3.0), acetonitrile and methanol (32:30:38) as the mobile phase at a flow rate of 1.0 mL/min with UV-detection at 215 nm. The method separated the four components simultaneously in less than 10 min. The validation of the method was performed with respect to specificity, linearity, accuracy, and precision. The calibration curves were linear in the range of 35.1-81.9 μ/mL for triacetin, 431.1-1005.9 μ/mL for acetic ether, 167.0-389.7 μ/mL for butyl acetate and 151.0-352.3 μ/mL for amorolfine. The mean 100% spiked recovery for triacetin, acetic ether, butyl acetate and amorolfine is 99.43 ± 0.42, 101.5 ± 1.09, 101.4 ± 1.02 and 100.8 ± 0.69, respectively. The intra-day and inter-day relative standard deviation values were <2.0%. The limits of detection of these compounds ranged from 0.08 to 5.88 ng. The utility of the procedure was verified by its application to the commercial liniment.

Download full-text PDF

Source

Publication Analysis

Top Keywords

acetic ether
16
butyl acetate
16
triacetin acetic
12
ether butyl
12
acetate amorolfine
12
amorolfine
5
simultaneous determination
4
triacetin
4
determination triacetin
4
acetic
4

Similar Publications

Objective: Study of 2.6-di(propan-2-yl)phenol (2.6-di(P-2-yl)F) distribution nature in warm-blooded in case of fatal poisoning due to intragastric administration of the substance.

View Article and Find Full Text PDF

Bruton's tyrosine kinase inhibitors (BTKis) exhibit significant interindividual pharmacokinetics, making therapeutic drug monitoring (TDM) a promising approach for personalized therapy. However, simultaneous quantification of multiple BTKis poses technical challenges. A unified protocol for BTKis detection would be clinically desirable.

View Article and Find Full Text PDF

[Chemical constituents from petroleum ether fraction of Artemisia stolonifera].

Zhongguo Zhong Yao Za Zhi

October 2024

State Key Laboratory for Quality Ensurance and Sustainable Use of Dao-di Herbs, National Resource Center for Chinese Materia Medica, China Academy of Chinese Medical Sciences Beijing 100700, China.

The chemical constituents in the petroleum ether fraction of Artemisia stolonifera were investigated. Twenty compounds(1-20) were isolated from the petroleum ether fraction of A. stolonifera by silica gel, Sephadex LH-20, and ODS chromatography and semi-preparative HPLC.

View Article and Find Full Text PDF

Various sanitation methods to recover helminth eggs are currently in use; however, no international standard exists. Development of such a method first involves testing the effects of all reagents used in current methods on helminth egg viability to determine whether these chemicals affect the test organism. This study was conducted to investigate the effects on viability and development of Ascaris suum eggs when exposed for various periods to wash solutions (water, ammonium bicarbonate, Tween® 20, Tween® 80, Triton® X-100, Sunlight® Liquid, bentonite, and 7X®), flotation solutions (zinc sulfate, magnesium sulfate, sodium nitrate, brine, and sucrose), extraction solutions (10% formalin, acetoacetic buffer, acid-alcohol, ethyl acetate, and diethyl ether), extraction combinations (10% formalin + ethyl acetate, 10% formalin + diethyl ether, acetoacetic buffer + ethyl acetate, acetoacetic buffer + diethyl ether, and acid-alcohol + ethyl acetate), and incubation solutions (water, 0.

View Article and Find Full Text PDF

Polyurethane (PUR) soft foams release malodorous and potentially toxic compounds when exposed to oxidative conditions. Current chamber test methods cannot distinguish between pre-existing volatiles and those formed during oxidation, nor can they assess the formation rates of oxidation products. We subjected PUR soft foam to oxidative treatment in a continuous air flow at 120 °C.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!