Ultraviolet radiation is known to cause both benefits and harmful effects on humans. The adverse effects mainly involve two target organs, skin and eye, and can be further divided into short- and long-term effects. The present case report describes an accidental exposure of two health-care workers to ultraviolet radiation produced by a germicidal lamp in a hospital pharmacy. The germicidal lamp presented a spectrum with an intense UV-C component as well as a modest UV-B contribution. Overexposure to UV-C radiation was over 100 times as large as the ICNIRP exposure limits. A few hours after the exposure, the two subjects reported symptoms of acute UV injury and both of them continued having significant clinical signs for over 2 years. In this study, we describe acute and potentially irreversible effects caused by high UV exposure. In addition, we present the results of risk assessment by occupational exposure to germicidal lamps.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1751-1097.2012.01151.xDOI Listing

Publication Analysis

Top Keywords

germicidal lamp
12
accidental exposure
8
radiation produced
8
produced germicidal
8
case report
8
risk assessment
8
ultraviolet radiation
8
exposure
5
radiation
4
exposure radiation
4

Similar Publications

The ocular safety of 222-nm far-ultraviolet-C (UV-C) irradiation, widely recognized for its germicidal properties, was evaluated in a clinical setting to assess its long-term health effects on the human eye. This prospective observational study involved a 36-month follow-up of physicians working in an ophthalmic examination room equipped with 222-nm UV-C lamps. Initially, a 12-month observation showed no signs of acute or chronic ocular damage.

View Article and Find Full Text PDF

Wavelength-specific inactivation mechanisms and efficacies of germicidal UVC for airborne human coronavirus.

J Hazard Mater

November 2024

School of Energy and Environment, City University of Hong Kong, Tat Chee Avenue, Kowloon, Hong Kong; Department of Architecture and Civil Engineering, City University of Hong Kong, Tat Chee Avenue, Kowloon, Hong Kong. Electronic address:

Ultraviolet germicidal irradiation (UVGI) technology can inhibit the environmental transmission of airborne pathogens, but the dose-response behavior of airborne human coronavirus and wavelength-specific inactivation mechanisms are not well understood. This study investigated three competitive UVC sources for their inactivation efficacy and mechanisms against human coronavirus OC43 (HCoV-OC43). Results showed the following order of inactivation efficacy: 222-nm KrCl excimer lamp > 263-nm UV-LEDs > 254-nm low-pressure mercury lamp.

View Article and Find Full Text PDF

Germicidal ultraviolet lamps with a peak emission at 222 nm (GUV222) are gaining prominence as a safe and effective solution to reduce disease transmission in occupied indoor environments. While previous studies have reported O production from GUV222, less is known about their impact on other indoor constituents affecting indoor air quality, especially in real occupied environments. In this study, the effects of GUV222 on the levels of ozone (O), ultrafine particles (UFPs), and volatile organic compounds (VOCs) were investigated across multiple offices with varying occupancies.

View Article and Find Full Text PDF

The Covid 19 pandemic has significantly affected the health, economy, and social impact of humanity. The continuous mutations of the virus variants have accelerated the demand for scientific research on disinfection techniques for a safer indoor environment. Among all the available surface disinfection techniques, ultraviolet germicidal irradiance at 254 nm wavelength has been proven for its disinfection efficacy; however, its usage is limited to unoccupied conditions due to the risk of ultraviolet exposure.

View Article and Find Full Text PDF

Human exposure to air contaminants under the far-UVC system operation in an office: effects of lamp position and ventilation condition.

Sci Rep

October 2024

Architectural Engineering Department, Pennsylvania State University, 408 Engineering Collaborative Research and Education (ECoRE) Building, University Park, PA, USA.

The far-UVC (222 nm) system has emerged as a solution for controlling airborne transmission, yet its effect on indoor air quality, particularly concerning positioning, remains understudied. In this study, we examined the impact of far-UVC lamp position on the disinfection and secondary contaminant formation in a small office. We employed a three-dimensional computational fluid dynamics (CFD) model to integrate UV intensity fields formed by different lamp positions (ceiling-mounted, wall-mounted, and stand-alone types) along with the air quality model.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!