Functional and aesthetic reconstruction after wide decompressive craniectomy directly correlates with subsequent quality of life. Advancements in the development of biomaterials have now made three-dimensional (3-D) titanium mesh a new option for the repair of skull defects after craniectomy. The purpose of this study was to review aesthetic and surgical outcomes and complications of patients who had skull defects repaired with 3-D titanium mesh. The records of 40 adult patients (31 unilateral craniectomies and 9 bilateral craniectomies) who underwent a computer-assisted designed titanium mesh implant at a university hospital from January 2008 to January 2010 were retrospectively reviewed. Aesthetic outcomes, cranial nerve V and VII function, and complications (hardware extrusions, meningitis, osteomyelitis, brain abscess, and pneumocephalus) were evaluated. The craniofacial symmetry, implant stability, and functional outcomes were excellent for all patients. No patients had trigeminal or facial dysfunction. All had excellent cosmetic results as measured by post-reduction radiographs and personal and family perceptions of the forehead contour. Two patients had delayed wound healing and subsequent subclinical wound infections, which resolved after treatment with antibiotics for 2 weeks. Craniofacial skeletal reconstruction with 3-D titanium mesh results in excellent forehead contour and cosmesis, and subsequently a better quality of life with few complications. Titanium mesh reconstruction offers a favorable alternative to other graft materials in the repair of large skull defects.

Download full-text PDF

Source
http://dx.doi.org/10.1089/neu.2011.2220DOI Listing

Publication Analysis

Top Keywords

titanium mesh
24
3-d titanium
12
skull defects
12
decompressive craniectomy
8
quality life
8
forehead contour
8
titanium
6
mesh
6
patients
5
reconstructive technologies
4

Similar Publications

Intracranial Hypotension Mechanism and Implant Retention Procedure for Patients With Titanium Mesh Exposure.

Oper Neurosurg (Hagerstown)

January 2025

Department of Neurosurgery, Huashan Hospital, Shanghai Medical College, Fudan University, Shanghai, China.

Background And Objectives: The study aimed to investigate the potential pathogenesis and present an implant retention procedure for patients with titanium mesh exposure after cranioplasty.

Methods: The clinical data were obtained from 26 consecutive cases with titanium mesh exposure who underwent surgical treatment between 2018 and 2023. These patients' medical records, scalp photographs, operative notes, and outcomes were retrospectively analyzed.

View Article and Find Full Text PDF
Article Synopsis
  • Cage subsidence can negatively affect lumbar fusion procedures, with material selection (PEEK vs. 3D-Ti) influencing this issue; the study aims to compare their subsidence rates.
  • The systematic search reviewed 265 patients from three high-quality studies, focusing on cage subsidence and classified subsidence rates using a specific method.
  • Results indicated that 3D-Ti cages have a significantly lower rate of subsidence compared to PEEK cages, with less severe subsidence and better overall performance.
View Article and Find Full Text PDF

Background: Anterior cervical corpectomy and fusion (ACCF) is a standard surgical procedure for cervical spondylosis with spinal cord compression (CSWSCC), especially in patients with intensity on T2-weighted imaging high signal (T2WIHS). The titanium mesh cage (TMC) utilized in this procedure is essential in stabilizing the spine; however, the optimal slotting width of the TMC remains unclear.

Objective: This study aimed to investigate the impact of TMC slotting width on the clinical and radiological outcomes of ACCF in patients with spinal cord compression type cervical spondylosis with intensity on T2WIHS (CST2WIHS).

View Article and Find Full Text PDF

Surgical management of costal margin rupture associated with intercostal hernia: Evolution of techniques.

J Trauma Acute Care Surg

October 2024

From the Sheffield Teaching Hospitals NHS Foundation Trust (P.W., J.N.R., S.T., J.G.E.), Sheffield, England; Erasmus Medical Centre (M.M.E.W.), Rotterdam, The Netherlands; and University Hospital of Southampton NHS Foundation Trust (A.T.).

Introduction: Costal margin rupture (CMR) injuries in association with intercostal hernia (IH) are rare and symptomatic and provide a significant surgical challenge. Surgical failure rates up to 60% are reported, and optimal techniques are unclear. We have characterized these injuries and describe the evolution of our surgical management techniques.

View Article and Find Full Text PDF

Introduction And Importance: Growing skull fracture is one the rarest complication of skull fracture. They are identified mostly in infancy and children's, secondary to head trauma but there exist possibility of missed diagnosis in childhood and patient presenting in adulthood with delayed complications. Hence timely diagnosis and prompt management is mandatory.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!