For evaluation of the spatial structure of chromatin in nuclei of mesenchymal SC we determined the position of centromeres and individual chromosomes in interphase nucleus of mesenchymal SC. More than 300 nuclei in 7 cultures of mesenchymal SC were analyzed. Centromeres of chromosomes 6, 8, and 11 lie at a longer (0.68, 0.67, 0.7), while centromere of chromosome 18 at a shorter radial distance (0.49). Homologues of each chromosome had different radial distances. No differences in radial distances of centromeres were detected between mesenchymal SC from the adipose tissue and BM. After passage 8, distal displacement of chromosome 6 centromere (from 0.66 to 0.72) was observed, which probably indicates aging or spontaneous differentiation of cells.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s10517-011-1370-4 | DOI Listing |
Small Methods
January 2025
School of Mechanical and Aerospace Engineering, Gyeongsang National University, Jinju, 52828, South Korea.
In various applications, the pore structure of a porous medium must be controlled to facilitate heat and mass transfer, which considerably influence the system performance. Freeze-casting is a versatile technique for creating aligned pores; However, because of the complexity of the associated equipment and the energy inefficiency of liquid-nitrogen-based cooling in a room-temperature environment, limits scalability for industrial applications. This study is aimed at establishing a novel freeze-casting strategy with a simple mold design combining heat-conductive and insulating materials for long-range pore alignment via directional ice growth under deep-freezing conditions, rendering it feasible for large-scale production.
View Article and Find Full Text PDFJ Clin Hypertens (Greenwich)
January 2025
Department of Geriatrics, Medical Center on Aging of Shanghai Ruijin Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, China.
The aim of this study was to explore whether 24-h ambulatory central (aortic) blood pressure (BP) has an advantage over office central aortic BP in screening for hypertension-mediated target organ damage (HMOD). A total of 714 inpatients with primary hypertension and the presence of several cardiovascular risk factors or complications involving clinical HMOD were enrolled. Twenty-four hour central aortic BP was measured by means of a noninvasive automated oscillometric device (Mobil-O-Graph).
View Article and Find Full Text PDFJ Hand Ther
January 2025
Program in Occupational Therapy, Center for Allied Health Programs, University of Minnesota, Minneapolis, MN, USA; Program in Rehabilitation Science, Medical School, University of Minnesota, Minneapolis, MN, USA.
Background: Limitations in thumb radial abduction (i.e., carpometacarpal extension) are commonly experienced by persons with thumb carpometacarpal osteoarthritis.
View Article and Find Full Text PDFJ Am Acad Orthop Surg
February 2025
From the Department of Orthopaedic Surgery, Keck Medical Center of the University of Southern California, Los Angeles, CA (Ihn, Chung, Lovro, Patterson, Christ, and Heckmann), the Department of Orthopaedic Surgery, Mayo Clinic, Rochester, MN (Chen), the Department of Orthopaedic Surgery, University of Pittsburgh, Pittsburgh, PA (Tucker), and the Department of Radiology, Keck Medical Center of the University of Southern California, Los Angeles, CA (White, and Hwang).
Introduction: Vascular injury during acetabular screw fixation is a life-threatening complication of total hip arthroplasty. This study uses three-dimensional computed tomography to (1) measure absolute distance from the external iliac artery (EIA) to the acetabulum, (2) determine available bone stock along the EIA path, and (3) create a novel acetabular vascular risk map.
Methods: A retrospective radiographic study was conducted using three-dimensional CT.
Langmuir
January 2025
Department of Chemical Engineering, University of Michigan, Ann Arbor, Michigan 48109, United States.
In this work, we show how shape matters for the ordering of red blood cells (RBCs) at a water-air interface for both artificially rigidified and sphered cells as a model system for hereditary spherocytosis. We report enhanced long-range order for spherical RBCs over disk-shaped RBCs arising from the increased local ordering of spheres relative to disks. We show that rigidity has a greater effect on the radial distribution of spherical vs disk-shaped RBCs by slightly increasing the average distance between cells.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!