In an effort to improve patient safety and reduce adverse events, there has been a rapid growth in the utilisation of health information technology (HIT). However, little work has examined the safety of the HIT systems themselves, the methods used in their development or the potential errors they may introduce into existing systems. This article introduces the conventional safety-related systems development standard IEC 61508 to the medical domain. It is proposed that the techniques used in conventional safety-related systems development should be utilised by regulation bodies, healthcare organisations and HIT developers to provide an assurance of safety for HIT systems. In adopting the IEC 61508 methodology for HIT development and integration, inherent problems in the new systems can be identified and corrected during their development. Also, IEC 61508 should be used to develop a healthcare-specific standard to allow stakeholders to provide an assurance of a system's safety.

Download full-text PDF

Source
http://dx.doi.org/10.1177/1460458211432587DOI Listing

Publication Analysis

Top Keywords

iec 61508
12
health technology
8
safety hit
8
hit systems
8
conventional safety-related
8
safety-related systems
8
systems development
8
provide assurance
8
systems
6
hit
5

Similar Publications

Is the safety index of modern safety integrity level(SIL) truly appropriate for the railway?

Accid Anal Prev

November 2023

National Engineering Research Center of Rail Transportation Operation and Control System, Beijing Jiaotong University, Beijing 100044, China; School of Electronic and Information Engineering, Beijing Jiaotong University, Beijing 100044, China.

Safety is paramount in rail transportation. The International Safety Standard IEC 61508, issued by the International Electrotechnical Commission (IEC) in 2000, describes the modern concept of safety and the specifications for safety evaluation in a systematic manner. On this basis, the EN 50129 railway transportation safety standard and safety integrity level(SIL) are established.

View Article and Find Full Text PDF

Generalizing PFD formulas of IEC 61508 for KooN configurations.

ISA Trans

March 2015

Siemens, Energy Sector, 160 Herring Road, Macquarie Park, 2113 NSW, Australia. Electronic address:

Detailed formulas are given in IEC 61508 for calculating Probability of Failure on Demand for 1oo1, 1oo2, 2oo2, 2oo3 and 1oo3 systems. Simplified PFD formulas are also derived for general k-out-of-n combinations, without incorporating all the elements utilized in IEC 61508 formulas. While there have been other studies on IEC 61508 formulas and the simplified k-out-of-n equations, none have proposed an inclusive generalized form of IEC 61508 formulas to replicate all the specific combinations covered by the standard.

View Article and Find Full Text PDF

In an effort to improve patient safety and reduce adverse events, there has been a rapid growth in the utilisation of health information technology (HIT). However, little work has examined the safety of the HIT systems themselves, the methods used in their development or the potential errors they may introduce into existing systems. This article introduces the conventional safety-related systems development standard IEC 61508 to the medical domain.

View Article and Find Full Text PDF

Modified risk graph method using fuzzy rule-based approach.

J Hazard Mater

May 2009

Safety Department, LARPI Laboratory, Institute of Health and Occupational Safety, University of Batna, Batna, Algeria.

The risk graph is one of the most popular methods used to determine the safety integrity level for safety instrumented functions. However, conventional risk graph as described in the IEC 61508 standard is subjective and suffers from an interpretation problem of risk parameters. Thus, it can lead to inconsistent outcomes that may result in conservative SILs.

View Article and Find Full Text PDF

Info-vigilance or safety in health information systems.

Stud Health Technol Inform

February 2002

Health Data Protection Ltd, Great Malvern, Worcs, England.

The paper examines the issues of security and safety in Health Information Systems and focuses the need for the development of appropriate Guidelines for the effective use of IEC 61508 standard.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!