Objectives/hypothesis: The purpose of this study is to review a consecutive series of patients with Zenker's diverticulum who were treated with endoscopic diverticulostomy using either the endoscopic stapler (ENDO GIA 30 Autosuture; Covidien, Dublin, Ireland) or Harmonic Ultrasonic Surgical Instrumentation (Ethicon Endo-Surgery, Cincinnati, OH) to evaluate the safety and optimal application of Harmonic technology to the treatment of patients with Zenker's diverticulum.
Study Design: This is a retrospective review at a tertiary academic hospital with institutional review board approval.
Methods: All patients undergoing endoscopic repair of Zenker's diverticulum between April 1, 2009 and December 1, 2010 at a single institution were studied.
Results: A total of 65 endoscopic diverticulostomies were performed: 24 Harmonic assisted, 41 stapler assisted. Average diverticulum size was 3.46 cm. There were two complications with staple-assisted (pharyngeal leak and recurrence) and six complications with Harmonic-assisted diverticulostomies (two pharyngeal leaks, two chest pains, one recurrence, and one subcutaneous emphysema). There was a statistically significant difference in the complication rates between the staple-assisted (4.88%) and Harmonic-assisted (25%) cohorts (P = .04). There were no complications with diverticula <2 cm.
Conclusions: Endoscopic Harmonic esophagodiverticulostomy has been reported for the treatment of Zenker's diverticula. However, our data demonstrate a significantly higher complication rate with use of the Harmonic technology compared to the staple-assisted method (P = .04). Additional evaluations are warranted to validate these findings and before Harmonic diverticulostomy can be recommended as treatment for the majority of cases.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/lary.23251 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!