Terahertz (THz) time-domain spectroscopy and 3D THz pulsed imaging have been explored with regard to polymer materials, both commodity and historic polymers. A systematic spectroscopic study of a wide range of different polymer materials showed significant differences in their spectra. Polyolefins and polystyrenes generally exhibit lower absorption than other examined polymers, various cellulose derivates, poly(vinyl chloride), poly(methyl methacrylate), polyamide, hard rubber and phenol formaldehyde resin, the last of these exhibiting the most intense absorption over the entire range, 0.15-4.2 THz. It was also examined how the presence of plasticisers in poly(vinyl chloride), the presence of fillers in polypropylene, and the degree of branching in polyethylene and polystyrene affect the spectra; inorganic fillers in polypropylene affected the absorption most. With 3D THz pulsed imaging, features in polymer objects were explored, appearing either as integral parts of the material (coatings and pores in foams) or as a consequence of physical deterioration (cracks, delamination). All of these features of various complexities can be successfully imaged in 3D. Terahertz technology is thus shown to have significant potential for both chemical and structural characterisation of polymers, which will be of interest to heritage science, but also to the polymer industry and development of analytical technologies in general.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00216-012-5931-9DOI Listing

Publication Analysis

Top Keywords

pulsed imaging
12
time-domain spectroscopy
8
thz pulsed
8
polymer materials
8
polyvinyl chloride
8
fillers polypropylene
8
characterisation historic
4
historic plastics
4
plastics terahertz
4
terahertz time-domain
4

Similar Publications

Capillary refill time paradoxically decreases in a blood loss shock model.

Intensive Care Med Exp

January 2025

Department of Emergency Medicine in Linköping, and Department of Biomedical and Clinical Sciences, Linköping University, 582 25, Linköping, Sweden.

Background: This study aimed to investigate whether changes in capillary refill (CR) time precede macrovascular signs of deterioration in a human model of blood loss shock. The study was conducted at the Department of Emergency Medicine in Linköping, Sweden, and involved 42 healthy volunteers aged 18-45. Participants were randomized into two provocations of applied lower body negative pressure (LBNP): a stepwise escalation protocol and a direct application protocol, to simulate gradual and acute blood loss.

View Article and Find Full Text PDF

Broadband coherent Fourier scatterometry: A two-pulse approach.

Rev Sci Instrum

January 2025

Optics Research Group, Imaging Physics Department, Delft University of Technology, Van der Waalsweg 8, 2628 CH Delft, The Netherlands.

We demonstrate a broadband implementation of coherent Fourier scatterometry (CFS) using a supercontinuum source. Spectral information can be resolved by splitting the incident field into two pulses with a variable delay and interfering them at the detector after interaction with the sample, bearing similarities with Fourier-transform spectroscopy. By varying the time delay between the pulses, a collection of diffraction patterns is captured in the Fourier plane, thereby obtaining an interferogram for every camera pixel.

View Article and Find Full Text PDF

Background: Extensive surgical resection of the thoracic aorta in patients with type A aortic dissection (TAAD) is thought to reduce the risk of late aortic wall degeneration and the need for repeat aortic operations.

Objectives: We evaluated the early and late outcomes after aortic root replacement and supracoronary ascending aortic replacement in patients with TAAD involving the aortic root.

Design: Retrospective, multicenter cohort study.

View Article and Find Full Text PDF

Ferroelectric and Optoelectronic Coupling Effects in Layered Ferroelectric Semiconductor-Based FETs for Visual Simulation.

Adv Sci (Weinh)

January 2025

Technical Center for Multifunctional Magneto-Optical Spectroscopy (Shanghai), Engineering Research Center of Nanophotonics & Advanced Instrument (Ministry of Education), Department of Physics, School of Physics and Electronic Science, East China Normal University, Shanghai, 200241, China.

Controlling polarization states of ferroelectrics can enrich optoelectronic properties and functions, offering a new avenue for designing advanced electronic and optoelectronic devices. Here, ferroelectric semiconductor-based field-effect transistors (FeSFETs) are fabricated, where the channel is a ferroelectric semiconductor (e.g.

View Article and Find Full Text PDF

Background: The optimal imaging modality for selecting the device size in patients with atrial fibrillation undergoing one-stop left atrial appendage occlusion (LAAO) with concomitant pulmonary vein isolation (PVi) remains undefined. We compared preprocedural 3-dimensional computed tomography (3D CT) with intra-procedural transesophageal echocardiography (TEE) and left atrial appendage (LAA) angiography in guiding one-stage PVi and LAAO.

Methods: We measured the LAA ostium diameter using an interactive 3D CT system with a central line-based approach and compared these measurements with those from intra-procedural TEE and angiography, and the actual device size.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!