Context: Pediatric cataract surgery is traditionally done with the aid of high-molecular-weight viscoelastics which are expensive. It needs to be determined if low-cost substitutes are just as successful.
Aims: The study aims to determine the success rates for anterior and posterior capsulorrhexis and intraocular lens (IOL) implantation in the bag for pediatric cataract surgery performed with the aid of a low-molecular-weight viscoelastic.
Settings And Design: Nonrandomized observational study.
Materials And Methods: Children less than 6 years of age who underwent cataract surgery with IOL implantation in the period May 2008-May 2009 were included. The surgeries were done by pediatric ophthalmology fellows. A standard procedure of anterior capsulorrhexis, lens aspiration with primary posterior capsulorrhexis, anterior vitrectomy, and IOL implantation was followed. Three parameters were studied: successful completion of anterior and posterior capsulorrhexis and IOL implantation in the bag.
Results: 33 eyes of 28 children were studied. The success rate for completion was 66.7% and 88.2 % for anterior and posterior capsulorrhexis, respectively. IOL implantation in the bag was successful in 87.9%.
Conclusions: 2% hydroxypropylmethylcellulose is a viable low-cost alternative to more expensive options similar to high-molecular-weight viscoelastics. This is of great relevance to hospitals in developing countries.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3339078 | PMC |
http://dx.doi.org/10.4103/0301-4738.90492 | DOI Listing |
J Ophthalmol
January 2025
Optics and Optometry Department, Universidad Complutense de Madrid, Madrid, Spain.
To analyze the refractive accuracy of a novel swept-source optical coherence biometer (SS-OCT), that uses individual refractive indices to measure axial length, in short and long eyes implanted with monofocal intraocular lenses (IOLs). This retrospective comparative study considered eyes with short axial length (AL) (< 22.5 mm) or long AL (> 26 mm) bilaterally implanted with the Acrysof IQ monofocal IOL.
View Article and Find Full Text PDFClin Ophthalmol
January 2025
Sengi, Penniac, NB, Canada.
Purpose: To evaluate visual outcomes and quality of vision following bilateral implantation of a hydrophobic acrylic intraocular lens (IOL) in eyes targeted for emmetropia.
Methods: This was a prospective, single arm study. Subjects were bilaterally implanted with the Clareon PanOptix IOL and evaluated at 1 and 3 months postoperatively.
J AAPOS
January 2025
Johns Hopkins University Wilmer Eye Institute, Baltimore, Maryland. Electronic address:
Background Recommendations regarding long-term postoperative activity are intended to prevent adverse events, but no common policy or best practice exists among ophthalmologists for pediatric patients. We surveyed ophthalmologists on their postoperative guidelines after the one-month postoperative period following childhood cataract and glaucoma surgeries. Methods A 28-question anonymous Qualtrics survey was distributed via listservs and social media.
View Article and Find Full Text PDFLife (Basel)
January 2025
Centro Oftalmológico Charles, Buenos Aiers C1116, Argentina.
Background: The aim of this study was to evaluate visual outcomes and patient satisfaction after bilateral implantation of a new hydrophobic acrylic intraocular lens called Clareon (Alcon) using the mini-monovision technique.
Methods: A single-center, prospective, nonrandomized study was conducted in Tandil (Buenos Aires, Argentina), including patients scheduled for cataract surgery. To achieve mini-monovision, the spherical equivalent was calculated between -0.
Biomedicines
January 2025
Department of Ophthalmology, UHC Sestre Milosrdnice, 10000 Zagreb, Croatia.
We describe a novel experimental device, the VaMa (Vatavuk and Marić) artificial intraocular lens (IOL) capsule, and a method that enables all IOL types to be implanted in the bag. We present the application of the device and the procedure in patients with aphakia and native capsule damage and without efficient capsular support. The VaMa device and the method facilitate IOL exchange due to refractive errors and, in the case of their invention, the implementation of superior IOLs in the future.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!