Duck Tembusu virus (DTMUV) has caused huge losses to the poultry industry in China since the spring of 2010. The development of a rapid, convenient, and reliable method to diagnose this emerging duck infectious disease is critical. In the present study, a real-time reverse transcription loop-mediated isothermal amplification (RT-LAMP) assay was compared with the real-time reverse transcription polymerase chain reaction (RT-PCR) for detection of DTMUV. The sensitivity of real-time RT-LAMP was equal to that of the real-time RT-PCR, with a detection limit of 0.01 ELD(50) (50% egg lethal dose). The specificity of the real-time RT-LAMP and real-time RT-PCR was confirmed using RNAs and DNAs extracted from related viruses which cause duck infections. The reproducibility of the real-time RT-PCR assay was better than that of the real-time RT-LAMP. Only three results from 96 tissue samples differed between the real-time RT-LAMP and this real-time RT-PCR, confirming the reliability of these methods. This study indicated that the real-time RT-LAMP is simpler, less time-consuming, and more convenient than the real-time RT-PCR. With its high sensitivity, specificity, and convenience, the real-time RT-LAMP is a practical molecular diagnostic method for rapid and quantitative detection of DTMUV infection in a resource-limited setting.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jviromet.2012.03.007DOI Listing

Publication Analysis

Top Keywords

real-time rt-lamp
24
real-time rt-pcr
20
real-time reverse
16
reverse transcription
16
real-time
14
transcription loop-mediated
8
loop-mediated isothermal
8
isothermal amplification
8
transcription polymerase
8
polymerase chain
8

Similar Publications

A novel ready-to-use loop-mediated isothermal amplification (LAMP) method for detection of Burkholderia mallei and B. pseudomallei.

BMC Microbiol

January 2025

Laboratory of Comparative Pathology, Faculty of Veterinary Medicine, Hokkaido University, Kita 18 Nishi 9, Kita-Ku, Sapporo, Hokkaido, 060-0818, Japan.

Background: Glanders and melioidosis are contagious zoonotic diseases caused by Burkholderia mallei and B. pseudomallei, respectively. Bacterial isolation and polymerase chain reaction (PCR) have been used to detect these bacteria in animals suspected of infection; however, both methods require skilled experimental techniques and expensive equipment.

View Article and Find Full Text PDF

Loop-mediated isothermal amplification (LAMP) is a detection method widely used in pathogen detection and clinical diagnosis. Nevertheless, it is highly constrained by thermal stability, catalytic activity, and resistance to inhibitors of Bst DNA polymerase. In this study, a novel DNA polymerase was characterized from Clostridium thermocellum, exhibiting potential in LAMP detection.

View Article and Find Full Text PDF

Introduction: f. sp. (Fol) is one of the most devastating plant pathogenic fungi, the causal agent of root rot for tractylides macrocephala Koidz (AMK).

View Article and Find Full Text PDF

Novel isothermal nucleic acid amplification method for detecting malaria parasites.

Appl Microbiol Biotechnol

December 2024

Laboratório de Pesquisa em Malária, Instituto Oswaldo Cruz (IOC), Fundação Oswaldo Cruz (Fiocruz), Rio de Janeiro, Brazil.

Article Synopsis
  • Malaria, caused by Plasmodium spp. and transmitted by Anopheles mosquitoes, remains a significant global health threat, with 249 million cases and 608,000 deaths reported in 2022.
  • The study evaluated the GENEYE® ERA Plasmodium detection kit for rapid and accurate malaria diagnosis in the Brazilian Amazon, comparing it with traditional methods like microscopy and rapid diagnostic tests (RDT).
  • Results indicated that the ERA test demonstrated 100% sensitivity alongside qPCR, while microscopy and RDT had lower sensitivity, highlighting the need for improved diagnostic tools in malaria-endemic regions.
View Article and Find Full Text PDF

Duck Tembusu virus (DTMUV) is an emerging flavivirus that has inflicted significant economic losses on China's poultry industry. Rapid and accurate detection of DTMUV is crucial for effective prevention and control measures. In this study, we developed a novel, rapid visual detection assay that combines reverse transcriptase loop-mediated isothermal amplification (RT-LAMP) with the CRISPR/Cas12a system for on-site detection of DTMUV.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!