A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Reliability and accuracy of a radiographic analysis method for posterior maxillary mini-implant location. | LitMetric

Objective: The purpose of this study was to evaluate the reliability and accuracy of a radiographic analysis method for the location of mini-implants inserted in the posterior region of the maxilla.

Material And Methods: Two self-drilling mini-implants were installed between the second premolar and the first molar on the right side and left side in three dry skulls. Three operators performed three occlusal radiographs, using an occlusal x-ray film holder, at three different times in each of the three skulls.

Results: The interclass correlation coefficient showed a significantly high, positive correlation (p<0.05), indicating an excellent reliability between operators. The analysis of variance showed no significant differences in time and among the operators.

Conclusion: Based of these findings, it may be concluded that this methodology can be used by several operators in longitudinal clinical studies on orthodontic mini-implants at the anterior-posterior and lateral-medial locations or longitudinal displacement.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3928780PMC
http://dx.doi.org/10.1590/s1678-77572012000100018DOI Listing

Publication Analysis

Top Keywords

reliability accuracy
8
accuracy radiographic
8
radiographic analysis
8
analysis method
8
three
5
method posterior
4
posterior maxillary
4
maxillary mini-implant
4
mini-implant location
4
location objective
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!