Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objective: : We report our experience with ultrasound augmented reality (US-AR) guidance for mitral valve prosthesis (MVP) implantation in the pig using off-pump, closed, beating intracardiac access through the Guiraudon Universal Cardiac Introducer attached to the left atrial appendage.
Methods: : Before testing US-AR guidance, a feasibility pilot study on nine pigs was performed using US alone. US-AR guidance, tested on a heart phantom, was subsequently used in three pigs (∼65 kg) using a tracked transesophageal echocardiography probe, augmented with registration of a 3D computed tomography scan, and virtual representation of the MVP and clip-delivering tool (Clipper); three pigs were used to test feature-based registration.
Results: : Navigation of the MVP was facilitated by the 3D anatomic display. AR displayed the MVP and the Clipper within the Atamai Viewer, with excellent accuracy for tool placement. Positioning the Clipper was hampered by the design of the MVP holder and Clipper. These limitations were well displayed by AR, which provided guidance for improved design of tools.
Conclusions: : US-AR provided informative image guidance. It documented the flaws of the current implantation technology. This information could not be obtained by any other method of evaluation. These evaluations provided guidance for designing an integrated tool: combining an unobtrusive valve holder that allows the MVP to function properly as soon as positioned, and an anchoring system, with clips that can be released one at a time, and retracted if necessary, for optimal results. The portability of Real-time US-AR may prove to be the ideal practical image guidance system for all closed intracardiac interventions.