Programmable valve shunts: are they really better?

Turk Neurosurg

Paras Hospital, Department of Neurosurgery, Gurgaon, Haryana, India.

Published: July 2012

Programmable valve shunts allows selection of opening pressure of shunt valve. In the presented article, a unique complication pertaining to programmable shunts has been discussed. A 5-year-old boy who had tectal plate low grade glioma with obstructive hydrocephalus was managed with Codman programmable ventriculoperitoneal shunt. There was a spontaneous change in the opening pressure of the shunt valve leading to shunt malfunction. Routinely used household appliances produce a magnetic field strong enough to cause change in the setting of shunt valve pressure and may lead to valve malfunction. Other causes of programmable valve malfunction also discussed.

Download full-text PDF

Source
http://dx.doi.org/10.5137/1019-5149.JTN.3011-10.1DOI Listing

Publication Analysis

Top Keywords

programmable valve
12
shunt valve
12
valve shunts
8
opening pressure
8
pressure shunt
8
valve malfunction
8
valve
6
programmable
5
shunt
5
shunts better?
4

Similar Publications

Purpose: Pre-procedural imaging is critical for transcatheter mitral valve repair planning in patients with mitral valve disease. As differences among various measurement techniques for valve evaluation are still poorly understood, we sought to assess the intra- and interobserver agreement of complex measurements derived from a prototype mitral evaluation tool (Siemens) and a commercially available tool (CVI42) using both saddle- and D-shaped mitral annulus techniques.

Materials And Methods: Multiphasic cardiac computed tomography angiography data were loaded into each software.

View Article and Find Full Text PDF

Background: Transcatheter closure of percutaneous paravalvular leak (PVL) is a technically challenging procedure, especially after surgical mechanical valve replacements (SMVR), as the risk of interference with the prosthetic valve discs and the complex interventional techniques required for mitral PVL closure. Our study was designed to review the results with transcatheter closure of PVL after SMVR.

Methods: From January 2018 through December 2023, a total of 64 patients with PVL after SMVR underwent transcatheter closure with the help of preoperative 3-dimensional printing model and simulator for image evaluation.

View Article and Find Full Text PDF

Background: The concomitant hiatal hernia repair with endoscopic fundoplication (c-TIF) is a novel anti-reflux procedure that addresses the hiatus and the gastro-esophageal flap valve for surgical candidates with GERD. We aim to compare the outcomes of a hiatal hernia repair with endoscopic fundoplication (TIF) vs surgical partial fundoplication (anterior and posterior) with regards to quality-of-life scores at 12 months after surgery.

Study Design: Following IRB approval, a prospectively maintained anti-reflux database was retrospectively reviewed to identify patients who underwent a c-TIF procedure or a surgical hiatal hernia repair with partial fundoplication.

View Article and Find Full Text PDF

Background: Cerebral autoregulation is a robust regulatory mechanism that stabilizes cerebral blood flow in response to reduced blood pressure, thereby preventing cerebral ischaemia. Scientists have long believed that cerebral autoregulation also stabilizes cerebral blood flow against increases in intracranial pressure, which is another component that determines cerebral perfusion pressure. However, this idea was inconsistent with the complex pathogenesis of normal pressure hydrocephalus, which includes components of chronic cerebral ischaemia due to mild increases in intracranial pressure.

View Article and Find Full Text PDF

Background And Objective: In clinical practice, valve-sparing aortic root replacement surgery primarily addresses left ventricular dysfunction in patients due to severe aortic regurgitation, but there is controversy regarding the choice of surgical technique. In order to investigate which type of valve-sparing aortic root replacement surgeries can achieve better blood flow conditions, this study examines the impact of changes in the geometric morphology of the aortic root on the hemodynamic environment through numerical simulation.

Methods: An idealized model of the aortic root was established based on data obtained from clinical measurements, including using the model of the aortic root without significant lesions as the control group (Model C), while using surgical models of leaflet reimplantation with tubular graft (Model T), leaflet reimplantation with Valsalva graft (Model V), and the Florida sleeve procedure (Model F) as the experimental groups.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!