Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objective: There is an increase of old patients needing aortic valve surgery. Especially in this age group, a lot of new less-invasive strategies are proposed. Our goal was to study whether a sutureless aortic valve, which is implanted surgically after removal of the native valve, could be an alternative for a subgroup of patients.
Methods: The Sorin Perceval S is a biologic pericardial aortic valve assembled in a metal super elastic alloy stent and implanted in the aortic root without the need of suturing. As part of a premarketing multicenter study (Cavalier trial), 34 patients were screened for Perceval S implantation. All patients underwent cardiopulmonary bypass and mini-invasive approach (partial upper sternotomy).
Results: Fourteen patients were excluded due to standardized criteria. Twenty patients received a 21-mm valve (2 patients), 23-mm valve (6 patients), or 25-mm valve (12 patients). X-clamp time was 20.6 ± 7.6 minutes, and implantation time was 8.6 ± 3.1 minutes. Intra- and postoperative echocardiography showed no paravalvular leakage, low gradients (max 16.3 ± 5, mean 9.8 ± 4.2), and two patients with an intraprosthesis reflux (one patient with 1/4+, one patient with 2/4+). All patients were discharged without major in-hospital complications (intensive care unit stay 1.4 ± 0.5 days, hospital stay 7 ± 0.7 days).
Conclusions: The sutureless Perceval S aortic valve is hemodynamically excellent and a safe prosthesis in selected patients. Due to a simple and fast implantation technique, this valve could guarantee a shorter operation time in combination with a mini-invasive approach.