Effect of release rate of the SF(6) tracer on methane emission estimates based on ruminal and breath gas samples.

Animal

UR1213 Herbivores, INRA Clermont-Ferrand/Theix, 63122 Saint-Genès-Champanelle, France.

Published: March 2012

The release rate (RR) of sulphur hexafluoride (SF(6)) gas from permeation tube in the rumen appears to be positively related with methane (CH(4)) emissions calculated using the SF(6) tracer technique. Gas samples of breath and ruminal headspace were collected simultaneously in order to evaluate the hypothesis that transactions of SF(6) in the rumen are the source for this relationship. Six non-lactating dairy cows fitted with rumen cannulae were subdivided into two groups and randomly assigned to a two-period crossover design to permeation tubes with low RR (LRR = 1.577 mg/day) or two-times higher RR (HRR = 3.147 mg/day) RR. The cows were fed limited amounts of maize silage (80% ad libitum) split into two meals (40% at 0800 h and 60% at 1600 h). Each period consisted of 3-day gas sampling. Immediately before the morning feed and then each hour over 8 h, ruminal gas samples (50 ml) were withdrawn through the cannula fitted with stoppers to prevent opening. Simultaneously, 8-h integrated breath gas samples were collected over the same period. Ratios of concentration of CH(4)/SF(6), CO(2)/SF(6) and CO(2)/CH(4) and emission estimates of CH(4) and CO(2) were calculated for each sample source using the SF(6) tracer technique principles. The LRR treatment yielded higher (P < 0.001) ruminal CH(4)/SF(6) (by 1.79 times) and CO(2)/SF(6) (by 1.90 times) ratios than the HRR treatment; however, these differences were lower than the 2.0 times difference expected from the RR between the LRR and HRR. Consequently, the LRR treatment was associated with lower (P < 0.01) ruminal emissions of CH(4) over the 8-h collection period than with the HRR treatment (+11%), a difference also confirmed by the breath samples (+11%). RR treatments did not differ (P = 0.53) in ruminal or breath CO(2) emissions; however, our results confirm that the SF(6) tracer seems inappropriate for CO(2) emissions estimation in ruminants. Irrespective of the RR treatment, breath samples yielded 8% to 9% higher CH(4) emission estimates than the ruminal samples (P = 0.01). The relationship between rumen and breath sources for CH(4) emissions was better for LRR than for HRR treatment, suggesting that tracer performance decreases with the highest RR of SF(6) tested in our study (3.1 mg/day). A hypothesis is discussed with regard to the mechanism responsible for the relationship between RR and CH(4) emission estimates. The use of permeation tubes with small range in RR is recommended in animal experiments to decrease variability in CH(4) emission estimates using the SF(6) tracer technique.

Download full-text PDF

Source
http://dx.doi.org/10.1017/S175173111100156XDOI Listing

Publication Analysis

Top Keywords

sf6 tracer
20
emission estimates
20
gas samples
16
tracer technique
12
hrr treatment
12
ch4 emission
12
release rate
8
sf6
8
ruminal breath
8
breath gas
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!