As part of the national initiative to reduce waiting times for joint replacement surgery in Wales, the Cardiff and Vale NHS Trust referred 224 patients to the NHS Treatment Centre in Weston-Super-Mare for total knee replacement (TKR). A total of 258 Kinemax TKRs were performed between November 2004 and August 2006. Of these, a total of 199 patients (232 TKRs, 90%) have been followed up for five years. This cohort was compared with 258 consecutive TKRs in 250 patients, performed at Cardiff and Vale Orthopaedic Centre (CAVOC) over a similar time period. The five year cumulative survival rate was 80.6% (95% confidence interval (CI) 74.0 to 86.0) in the Weston-Super-Mare cohort and 95.0% (95% CI 90.2 to 98.2) in the CAVOC cohort with revision for any reason as the endpoint. The relative risk for revision at Weston-Super-Mare compared with CAVOC was 3.88 (p < 0.001). For implants surviving five years, the mean Oxford knee scores (OKS) and mean EuroQol (EQ-5D) scores were similar (OKS: Weston-Super-Mare 29 (2 to 47) vs CAVOC 29.8 (3 to 48), p = 0.61; EQ-5D: Weston-Super-Mare 0.53 (-0.38 to 1.00) vs CAVOC 0.55 (-0.32 to 1.00), p = 0.79). Patients with revised TKRs had significantly lower Oxford knee and EQ-5D scores (p < 0.001). The results show a higher revision rate for patients operated at Weston-Super-Mare Treatment Centre, with a reduction in functional outcome and quality of life after revision. This further confirms that patients moved from one area to another for joint replacement surgery fare poorly.

Download full-text PDF

Source
http://dx.doi.org/10.1302/0301-620X.94B4.27978DOI Listing

Publication Analysis

Top Keywords

treatment centre
12
total knee
8
nhs treatment
8
centre weston-super-mare
8
joint replacement
8
replacement surgery
8
cardiff vale
8
oxford knee
8
scores oks
8
eq-5d scores
8

Similar Publications

Background: As iatrogenic hyperoxia has been related to adverse outcomes in critically ill patients, guidelines advise to titrate oxygen to physiological levels. In the prehospital setting where partial arterial oxygen (PaO) values are often not readily available, titration of oxygen is based on peripheral oxygen saturations (SpO2). In this study we aimed to investigate the efficacy of SpO guided oxygen titration in the prevention of hyperoxia.

View Article and Find Full Text PDF

Background: Nitrous oxide (N₂O), commonly known as laughing gas, is widely recognized for its anesthetic and analgesic effects, and is frequently used in medical contexts. However, its misuse can lead to significant neurological complications, which are often under-recognized in clinical practice. Recent data on such cases in Germany are rare.

View Article and Find Full Text PDF

Background: Bulbar function is frequently impaired in patients with spinal muscular atrophy (SMA). Although extremely important for the patient's quality of life, it is difficult to address therapeutically. Due to bulbar dysfunction, maximum mouth opening (MMO) is suspected to be reduced in children with SMA.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!