Giant spin-dependent thermoelectric effect in magnetic tunnel junctions.

Nat Commun

Institut Jean Lamour, Nancy-Université, Boulevard des Aiguillettes, BP 239, Vandoeuvre-lès-Nancy 54506, France.

Published: March 2012

Thermoelectric effects in magnetic nanostructures and the so-called spin caloritronics are attracting much interest. Indeed it provides a new way to control and manipulate spin currents, which are key elements of spin-based electronics. Here we report on a giant magnetothermoelectric effect in a magnetic tunnel junction. The thermovoltage in this geometry can reach 1 mV. Moreover a magnetothermovoltage effect could be measured with ratio similar to the tunnel magnetoresistance ratio. The Seebeck coefficient can then be tuned by changing the relative magnetization orientation of the two magnetic layers in the tunnel junction. Therefore, our experiments extend the range of spintronic devices application to thermoelectricity and provide a crucial piece of information for understanding the physics of thermal spin transport.

Download full-text PDF

Source
http://dx.doi.org/10.1038/ncomms1748DOI Listing

Publication Analysis

Top Keywords

magnetic tunnel
8
tunnel junction
8
giant spin-dependent
4
spin-dependent thermoelectric
4
magnetic
4
thermoelectric magnetic
4
tunnel
4
tunnel junctions
4
junctions thermoelectric
4
thermoelectric effects
4

Similar Publications

Soil magnetic records in Quaternary red earth (QRE) deposits contain a valuable record of paleoclimate information, providing insights into controls on Earth's climate system in the past and potentially helping to predict its response to perturbations in the future. Here, analysis of the environmental magnetism and mineralogy of the Xuancheng QRE (Anhui Province, South China) shows that magnetic variation was strongly linked to production of authigenic ferrimagnetic minerals such as maghemite. Fine-grained maghemite formed during the weathering-related transformation of iron-bearing illite to vermiculite, generating aggregates of vermiculite or mixed-layer illite-vermiculite.

View Article and Find Full Text PDF

Mapping the myomagnetic field of a straight and easily accessible muscle after electrical stimulation using triaxial optically pumped magnetometers (OPMs) to assess potential benefits for magnetomyography (MMG). Approach: Six triaxial OPMs were arranged in two rows with three sensors each along the abductor digiti minimi (ADM) muscle. The upper row of sensors was inclined by 45° with respect to the lower row and all sensors were aligned closely to the skin surface without direct contact.

View Article and Find Full Text PDF

Variations of the ankle anatomy are infrequent and exist as supernumerary muscles and tendons. Often understudied and overlooked, their presence can cause many complications of the lower extremity. These muscles, although often asymptomatic, can cause great pain and complications such as tenosynovitis, tarsal tunnel syndrome, lateral ankle instability, and ankle pain when they impinge on the normal anatomy of the patient.

View Article and Find Full Text PDF

Diagnosing peroneus brevis split tears is a significant challenge, as many cases are missed both clinically and on imaging. Anatomical variations within the superior peroneal tunnel can contribute to peroneus brevis split tears or instability of the peroneal tendons. However, determining which anatomical variations predispose patients to these injuries remains challenging due to conflicting data in the literature.

View Article and Find Full Text PDF

A new compound [Y(sq)(HO)] (Y-sq; sq = squarate (CO)) was prepared and structurally characterized. Since the RE-sq family (RE = Y, Dy, Yb, Lu) gave isostructural crystals, the objective of this study is to explore the effects of diamagnetic dilution on the SIM behavior through systematic investigation and comparison of diamagnetically diluted and undiluted forms. The 1%-Diluted Dy compounds, Dy@Y-sq and Dy@Lu-sq, showed AC magnetic susceptibility peaks without any DC bias field (), whereas undiluted Dy-sq showed no AC out-of-phase response under the same conditions.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!